We evaluated the preoperative errors in the pelvic tilt of 249 hips before total hip arthroplasty using fluoroscopic imaging while the patients were in the lateral decubitus position. The mean absolute value errors of the pelvic tilt were 2.94° (SD, 2.92°), 2.49° (SD, 2.68°), and 5.92° (SD, 5.20°) in the coronal, transverse, and sagittal planes, respectively. Such preoperative errors in the pelvic tilt contribute to malpositioning of the acetabular component, as is frequently observed on postoperative radiographs. We reduced the incidence of malpositioning by correcting the errors in the pelvic tilt through repositioning of the operating table using fluoroscopic imaging before surgery. The new technique using fluoroscopic imaging described in this article can be performed within a short time without a navigation system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopic Imaging of Acetabular Cup Position During THA Through a Direct Anterior Approach

Two main causes of postoperative total hip arthroplasty (THA) dislocation are malposition of the acetabular component within the prosthesis and soft tissue imbalances.1 The direct anterior approach for THA is viewed as advantageous compared with other approaches because, in addition to preserving many of the inherent restraints within the hip joint,2 it allows C-arm fluoroscopy image intensifie...

متن کامل

Fluoroscopic imaging of acetabular cup position during THA through a direct anterior approach.

Mobile image intensifiers are more readily used to assess acetabular cup placement when performing a total hip arthroplasty through a direct anterior approach. However, patient positioning affects pelvic tilt and rotation, which in turn requires proper C-arm fluoroscopy adjustments for image interpretation. The authors provide insight into the interpretation of acetabular cup positioning based ...

متن کامل

Effects of Spinopelvic Balance on Acetabular Version in Total Hip Arthroplasty

The orientation of acetabular component is influenced by pelvic tilt, body position and individual variation in pelvic parameters. Most adverse events attribute to improper positioning of the acetabular component in the functional position. There is evidence that the orientation of the pelvis changes from the supine to standing position, consequently changing the orientation of acetabular cup v...

متن کامل

Open reduction and internal fixation aided by intraoperative 3-dimensional imaging improved the articular reduction in 72 displaced acetabular fractures

BACKGROUND AND PURPOSE During acetabular fracture surgery, the acetabular roof is difficult to visualize with 2-dimensional fluoroscopic views. We assessed whether intraoperative 3-dimensional (3D) imaging can aid the surgeon to achieve better articular reduction and improve implant fixation. PATIENTS AND METHODS We operated on 72 acetabular fractures using intraoperative 3D imaging and compa...

متن کامل

Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 26 7  شماره 

صفحات  -

تاریخ انتشار 2011