Comparison of optimized fast spin echo (FSE) magnetic resonance (MR) imaging to view angle tilt (VAT) FSE in the reduction of metallic susceptibility artifact surrounding arthroplasty

نویسندگان

  • L. F. Foo
  • S. T. Jawetz
  • K. Butts Pauly
  • H. G. Potter
چکیده

Introduction / Background: MR imaging of arthroplasty has traditionally been limited by the presence of artifact generated by the metallic components, which comparatively demonstrate higher magnetic susceptibility than the adjacent bone and soft tissue (1-3). The sources of these artifacts include induction of radiofrequency eddy currents in the metal, warping of the slice during slice selection, and in-plane off resonance chemical and susceptibility misregistration in the frequency-encoding direction. The intensity of the artifact is related to the degree of relative ferromagnetism of the components, their orientation relative to the external field, as well as the geometry of the implant (1). Metallic susceptibility artifact can be minimized with modification of MR pulse sequence parameters, including the use of a wider receiver bandwidth to minimize the chemical shift generated at the metal-bone and metal-soft tissue interface, as well as high spatial resolution in the frequency direction. View angle tilt (VAT) is an additional method aimed at reducing in-plane geometric distortion from off resonance by adding a gradient in the slice-select axis during signal readout (4,5). The purpose of this study was to make a qualitative comparison of optimized fast spin echo (FSE) MR images to images obtained with VAT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The FSE Cusp Artifact: A Phase Wrap-In Artifact Seen on Routine Clinical MR Images of the Knee

In the course of routine fast spin echo (FSE) magnetic resonance (MR) imaging of knees, we have noticed a distinct and recurrent artifact on MR sagittal knee images. The artifact usually appears as a focal dot of high signal intensity and/or c-shaped ripples at a non-orthogonal angle (Figure 1). The technical features of this artifact have been previously described in an ISMRM abstract in 1995,...

متن کامل

New MR imaging methods for metallic implants in the knee: artifact correction and clinical impact.

PURPOSE To evaluate two magnetic resonance imaging (MRI) techniques, slice encoding for metal artifact correction (SEMAC) and multiacquisition variable-resonance image combination (MAVRIC), for their ability to correct for artifacts in postoperative knees with metal. MATERIALS AND METHODS A total of 25 knees were imaged in this study. Fourteen total knee replacements (TKRs) in volunteers were...

متن کامل

Magnetic resonance imaging of knee cartilage using a water selective balanced steady-state free precession sequence.

PURPOSE To compare an optimized water selective balanced steady-state free precession sequence (WS-bSSFP) with conventional magnetic resonance (MR) sequences in imaging cartilage of osteoarthritic knees. MATERIALS AND METHODS Flip angles of sagittal and axial WS-bSSFP sequences were optimized in three volunteers. Subsequently, the knees of 10 patients with generalized osteoarthritis were imag...

متن کامل

Neuro MR: principles.

The principles of contrast mechanisms and fast pulse sequences underlying neurological and neuroradiological application of MRI are introduced in this part of a two-part review. In particular, the relaxation time constants T(1), T(2), and T(2) (*) are introduced, along with pulse sequences harnessing their contrast, spin-echo, fast spin echo (FSE), inversion recovery (IR), gradient recalled ech...

متن کامل

A comparison of conventional spin-echo and fast spin-echo in the detection of multiple sclerosis.

Fast spin-echo (FSE) pulse sequences enable T2-weighted imaging in a fraction of the time required for T2-weighted conventional spin-echo (CSE) imaging. Due to concerns that the altered contrast characteristics of FSE may interfere with the visualization of multiple sclerosis (MS) lesions, the sensitivity of T2-weighted FSE sequences was compared to comparably weighted CSE sequences in the imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007