MINI INVASIVE SURGERY in KNEE ARTHROPLASTY
ثبت نشده
چکیده
-visual exposure Most of the time, knee prosthesis doesn’t require a long standard approach everting the patella and cuting extensor mechanism on a long distance. On the opposite, MIS is not operating through a keyhole. Lenght of the skin incision is not the most important even if it is the main thing that the patient will see postoperatively. But when it is possible to do it with a small incision why not to do it?
منابع مشابه
Minimum 5-year Follow-up Results of Minimally Invasive Total Knee Arthroplasty Using Mini-Keel Modular Tibial Implant
PURPOSE To evaluate the minimum 5-year mid-term clinical and radiological results of minimally invasive surgery total knee arthroplasty (MIS-TKA) using a mini-keel modular tibia component. MATERIALS AND METHODS We retrospectively evaluated 254 patients (361 cases) who underwent MIS-TKA between 2005 and 2006. The latest clinical and radiological assessments were done in 168 cases that had been...
متن کاملPartial 2-Stage Revision in Chronic Hip Arthroplasty Infections: A Review
Background: Periprosthetic hip infections (PHIs) are troublesome complications of hip arthroplasties. The gold standard procedure for treating chronic PHI is a 2-stage approach. Recently, however, more conservative approaches have been developed to spare the osseointegrated components and avoid sequestra, bone loss, devascularization, and difficult reconstructions. The partial ...
متن کاملDeviation between navigated and final 3-dimensional implant position in mini-invasive unicompartmental knee arthroplasty
BACKGROUND AND PURPOSE Unicompartmental knee arthroplasty (UKA) is an established method of treating isolated gonartrosis. Modern techniques such as computer-assisted surgery (CAS) and minimally invasive surgery (MIS) are attractive complementary methods to UKA. However, the positioning of the components remains a concern. Thus, we performed a prospective study to assess whether there was devia...
متن کاملMid-term survivorship of cruciate-retaining versus posterior-stabilized total knee arthroplasty using modular mini-keel tibial implants
BACKGROUND Reports of diverse outcomes in modular mini-keel tibial componentry for total knee arthroplasty (TKA) have raised concerns about early aseptic loosening. Cruciate-retaining (CR) prostheses, using mini-keel implants, have yet to be reported and compared to posterior-stabilizing (PS) designs. METHODS A retrospective, case-matched study of 91 consecutive TKAs (n = 46 CR; n = 45 PS pro...
متن کاملConservative Bone Cuts and Technical Hints Incruciate Retaining Total Knee Arthroplasty, a 20 Years Experience
Total knee arthroplasty (TKA) is one of the most successful procedures in modern orthopedic surgery, providing high patient satisfaction rate. As a result, the number of patients undergoing TKA is increasing in number every year and more patients would be inclined to have the operation in near future . The demand for TKA is expected to grow 673% between 2005 and 2030. Knee surgeons are using mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007