Liver CT Multiphase Image Registration and a Fast Algorithm for Its Numerical Approximation

نویسنده

  • Meng Lu
چکیده

Abstract Contrast-enhanced multiphase liver CT is currently a standard of practice in hepatic imaging for medical diagnosis of liver diseases. We presented a novel image registration method for liver CT multiphase images. Firstly, a biomechanical model is proposed to describe the procedure of image registration, and expressed by an energy function. Then the numerical approximation of the energy function based on three dimensional Level-Set method is implemented which is accelerated by Compute Unified Device Architecture (CUDA) to make sure that our method can meet the clinical real-time requirement. Experiments show that our method can accurately register liver CT multiphase images. And compared with other algorithm, our method is much faster, and higher the image resolution is, bigger the speed-up ration is.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...

متن کامل

An Estimation of Multiphase Relative Permeabilities in Reservoir Cores from Micro-CT Data

With significant increase of tomographic equipment power, demand for Prediction relative permeability prediction Predicting in porous media from digital image data. In this work, it is predicted three -phase relative permeabilities with co-applying Darcy’s and Stokes equations in two case studies, namely Bentheimer sandstone and Estaillades limestone which their micro-CT data files were downloa...

متن کامل

Efficient Feature-Based Nonrigid Registration of Multiphase Liver CT Volumes

This paper presents an efficient feature-based nonrigid registration method for multiphase liver CT volumes. While radiologists routinely examine multiphase liver CT to detect hepatic diseases, they usually search corresponding points between 3D CT volumes by visual inspections using 2D slice images. As the liver is a deformable organ, there exist complex nonrigid transformations between liver ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013