An algorithm to extract three‐dimensional motion by marker tracking in the kV projections from an on‐board imager: four‐dimensional cone‐beam CT and tumor tracking implications
نویسندگان
چکیده
The purpose of this work is to extract three-dimensional (3D) motion trajectories of internal implanted and external skin-attached markers from kV cone-beam projections and reduce image artifact from patient motion in cone-beam computed tomography (CBCT) from on-board imager. Cone beam radiographic projections were acquired for a mobile phantom and liver patients with internal implanted and external skin-attached markers. An algorithm was developed to automatically find the positions of the markers in the projections. It uses normalized cross-correlation between a template image of a metal seed marker and the projections to find the marker position. From these positions and time-tagged angular views, the marker 3D motion trajectory was obtained over a time interval of nearly one minute, which is the time required for scanning. This marker trajectory was used to remap the pixels of the projections to eliminate motion. Then, the motion-corrected projections were used to reconstruct CBCT. An algorithm was developed to extract 3D motion trajectories of internal and external markers from cone-beam projections using a kV monoscopic on-board imager. This algorithm was tested and validated using a mobile phantom and patients with liver masses that had radio-markers implanted in the tumor and attached to the skin. The extracted motion trajectories were used to investigate motion correlation between internal and external markers in liver patients. Image artifacts from respiratory motion were reduced in CBCT reconstructed from cone-beam projections that were preprocessed to remove motion shifts obtained from marker tracking. With this method, motion-related image artifacts such as blurring and spatial distortion were reduced, and contrast and position resolutions were improved significantly in CBCT reconstructed from motion-corrected projections. Furthermore, correlated internal and external marker 3D-motion tracks obtained from the kV projections might be useful for 4DCBCT, beam gating and tumor motion monitoring or tracking.
منابع مشابه
Evaluation of the effects of sagging shifts on isocenter accuracy and image quality of cone‐beam CT from kV on‐board imagers *
To investigate the effects of sagging shifts of three on-board kV imaging systems (OBI) on the isocenter positioning accuracy and image quality of cone-beam CT (CBCT). A cubical phantom having a metal marker in the center that can be aligned with the radiation isocenter was used to measure sagging shifts and their variation with gantry angle on three Varian linacs with kV on-board imaging syste...
متن کاملFour-dimensional cone-beam computed tomography and digital tomosynthesis reconstructions using respiratory signals extracted from transcutaneously inserted metal markers for liver SBRT.
PURPOSE Respiration-induced intrafraction target motion is a concern in liver cancer radiotherapy, especially in stereotactic body radiotherapy (SBRT), and therefore, verification of its motion is necessary. An effective means to localize the liver cancer is to insert metal fiducial markers to or near the tumor with simultaneous imaging using cone-beam computed tomography (CBCT). Utilizing the ...
متن کاملFirst demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking.
PURPOSE For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. METHODS AND MATERIALS The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millenniu...
متن کاملDynamic MLC tracking of moving targets with a single kV imager for 3D conformal and IMRT treatments.
BACKGROUND Tumor motion during radiotherapy is a major challenge for accurate dose delivery, in particular for hypofractionation and dose painting. The motion may be compensated by dynamic multileaf collimator (DMLC) tracking. Previous work has demonstrated that a single kV imager can accurately localize moving targets for DMLC tracking during rotational delivery, however this method has not be...
متن کاملDynamic multileaf collimator tracking of respiratory target motion based on a single kilovoltage imager during arc radiotherapy.
PURPOSE To demonstrate and characterize dynamic multileaf collimator (DMLC) tracking of respiratory moving targets that are spatially localized with a single kV X-ray imager during arc radiotherapy. METHODS AND MATERIALS During delivery of an arc field (358 degrees gantry rotation, 72-sec duration, circular field shape), the three-dimensional (3D) position of a fiducial marker in a phantom wa...