Influence of the shape of the pacing pulse on ventricular excitation threshold and the function of skeletal muscles in the operating field during non-invasive transcutaneous cardiac pacing under general anaesthesia.
نویسندگان
چکیده
BACKGROUND Transcutaneous cardiac pacing (TCP) in patients under general anesthesia does not pose a problem of pain threshold for high amplitudes of pacing pulses, but their application causes contractions of skeletal muscles, which is a problem during surgery. Evaluation of the influence of various shapes of the pacing pulse on the ventricular excitation threshold, the electric energy transmitted to the system of electrodes and the movement of the operating field during TCP performed under general anesthesia. METHODS The study included 58 patients operated under general anesthesia with TCP performed subsequently by means of rectangular pulses, square of the sinus and root of the sinus shaped pulses with identical pulse base width of 40 ms. RESULTS With incomplete muscle relaxation, for the amplitudes of up to 120 mA, the pacing was the most efficient (94%), ventricular excitation thresholds (VET) were the lowest, i.e. 70.5 +/- 18.3 mA on average, and the operating field was the most stable when rectangular pulse was applied. The lowest electrical energy, i.e. 44.0 +/- 13.8 mJ on average, was provided to the system of electrodes by the pulse shaped like the square of the sinus. The rectangular pulse caused the earliest excitation of skeletal muscles at 40.5 +/- 15.6 mA on the average. However, in the conditions of complete muscle relaxation, the skeletal muscle excitation thresholds doubled, which greatly reduced the movement of the operating field. CONCLUSIONS The rectangular pacing pulse ensured the lowest VET, the least movement of the operating field and the most efficient pacing during TCP under general anesthesia. The square of the sinus shaped pulse allowed for the lowest electrical energy applied to the heart. Owing to full skeletal muscle relaxation, the surgeon operated in a stable operating field. (Cardiol J 2007; 14: 137-142).
منابع مشابه
Effect of Cell Size and Shape on Electric Field Threshold and Critical Transmembrane Voltage for Electroporation
Introduction: Electroporation is a technique for increasing the permeability of the cell membrane to otherwise non-permeate molecules due to an external electric field. This permeability enhancement is detectable if the induced transmembrane voltage becomes greater than a critical value which depends on the pulse strength threshold. In this study, the variabil...
متن کاملPacemaker Twiddler's Syndrome
A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...
متن کاملHyperkalemia-induced complete heart block
Background: Potassium, as an extracellular ion, plays an important role in the electrophysiologic function of the myocardium and any change in extracellular concentration of this ion might have a marked impression upon myocyte electrophysiologic gain. High serum potassium levels are thought to impair pulse conduction in Purkinje fibers and ventricles more than that in the Atrio...
متن کاملبلوک کامل قلبی مادرزادی، معرفی یک مورد و مرور مقالات مشابه
Abstract: Background and Aim: Since electrocardiography (ECG) is essential for the diagnosis of pediatric asymptomatic Complete Heart Block (CHB) and it is not usually done in the preoperative evaluation of asymptomatic children, physicians might confront with asymptomatic cases of CHB at anesthesia induction. Case Report: In this study, we introduced a 31-month-old boy who faced CHB after anes...
متن کاملChanges in pulse pressure variability during cardiac resynchronization therapy in mechanically ventilated patients
INTRODUCTION The respiratory variation in pulse pressure (PP) has been established as a dynamic variable of cardiac preload which indicates fluid responsiveness in mechanically ventilated patients. The impact of acute changes in cardiac performance on respiratory fluctuations in PP has not been evaluated until now. We used cardiac resynchronization therapy as a model to assess the acute effects...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiology journal
دوره 14 2 شماره
صفحات -
تاریخ انتشار 2007