Unified segmentation based correction of R1 brain maps for RF transmit field inhomogeneities (UNICORT)

نویسندگان

  • Nikolaus Weiskopf
  • Antoine Lutti
  • Gunther Helms
  • Marianne Novak
  • John Ashburner
  • Chloe Hutton
چکیده

Quantitative mapping of the longitudinal relaxation rate (R1=1/T1) in the human brain enables the investigation of tissue microstructure and macroscopic morphology which are becoming increasingly important for clinical and neuroimaging applications. R1 maps are now commonly estimated from two fast high-resolution 3D FLASH acquisitions with variable excitation flip angles, because this approach is fast and does not rely on special acquisition techniques. However, these R1 maps need to be corrected for bias due to RF transmit field (B1(+)) inhomogeneities, requiring additional B1(+) mapping which is usually time consuming and difficult to implement. We propose a technique that simultaneously estimates the B1(+) inhomogeneities and R1 values from the uncorrected R1 maps in the human brain without need for B1(+) mapping. It employs a probabilistic framework for unified segmentation based correction of R1 maps for B1(+) inhomogeneities (UNICORT). The framework incorporates a physically informed generative model of smooth B1(+) inhomogeneities and their multiplicative effect on R1 estimates. Extensive cross-validation with the established standard using measured B1(+) maps shows that UNICORT yields accurate B1(+) and R1 maps with a mean deviation from the standard of less than 4.3% and 5%, respectively. The results of different groups of subjects with a wide age range and different levels of atypical brain anatomy further suggest that the method is robust and generalizes well to wider populations. UNICORT is easy to apply, as it is computationally efficient and its basic framework is implemented as part of the tissue segmentation in SPM8.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction of Rf Inhomogeneities in Flash-based T1 Mapping Using Unified Segmentation

Introduction: Quantitative T1 mapping based on 3D FLASH acquisitions with variable excitation flip angles (VFA) is fast and robust (1, 2). However, high accuracy can only be achieved when the local flip angle is known precisely (1). At higher static magnetic fields local flip angles may deviate considerably from the nominal flip angle due to inhomogeneities of the RF transmit/B1 field (3, 4). T...

متن کامل

New Developments and Applications of the MP2RAGE Sequence - Focusing the Contrast and High Spatial Resolution R1 Mapping

MR structural T1-weighted imaging using high field systems (>3T) is severely hampered by the existing large transmit field inhomogeneities. New sequences have been developed to better cope with such nuisances. In this work we show the potential of a recently proposed sequence, the MP2RAGE, to obtain improved grey white matter contrast with respect to conventional T1-w protocols, allowing for a ...

متن کامل

Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation

Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2011