Relationship between electrophysiological, psychophysical, and anatomical measurements in glaucoma.

نویسندگان

  • David F Garway-Heath
  • Graham E Holder
  • Fred W Fitzke
  • Roger A Hitchings
چکیده

PURPOSE To evaluate the relationship between electrophysiological, psychophysical, and structural measurements in normal and glaucomatous eyes and to test the hypothesis that there is a continuous structure-function relationship between ganglion cell numbers and visual field sensitivity. METHODS Thirty-four normal subjects and 40 patients with glaucoma were examined with the pattern electroretinogram (PERG), perimetry and retinal tomography. Transient and steady state (SS) PERGs were recorded, and peak (P)-to-trough (N) amplitude was measured. The unit of differential light sensitivity (DLS) in perimetry is the decibel. The decibel is 10. log(1/Lambert), where the Lambert is the unit of test spot intensity. PERG amplitudes were correlated with decibel and 1/Lambert DLS for the central 18 degrees of the visual field and with neuroretinal rim area in the temporal part of the optic disc. Age-related changes in the structural and functional measurements were sought. The correlation between variables was investigated by linear and quadratic regression analysis. A quadratic (y = ax + bx(2) + c) fit was taken to be significantly better than a linear fit, if the coefficient (b) for the x(2) term was significant at P < 0.05. RESULTS A quadratic fit between decibel DLS and PERG amplitude (transient PERG: R(2) = 0.40, P = 0.0000; SS PERG: R(2) = 0.32, P = 0.0000) was significantly better than a linear fit. There was a linear correlation between 1/Lambert DLS and PERG amplitude (transient PERG: R(2) = 0.44, P = 0.0000; SS PERG: R(2) = 0.35, P = 0.0000). There was a linear correlation between temporal neuroretinal rim area and PERG amplitude (transient PERG: R(2) = 0.17, P = 0.0003; SS PERG: R(2) = 0.20, P = 0.0001). A quadratic fit between decibel DLS and temporal neuroretinal rim area (R(2) = 0.38, P = 0.0000) was significantly better than a linear fit. There was a linear correlation between 1/Lambert DLS and temporal neuroretinal rim area (R(2) = 0.30, P = 0.0000). Both DLS and PERG amplitude declined with age in the normal subjects. The rate of decline was -0.17%, -0.74%, -0.75%, and -0.78% per year for decibel DLS, 1/Lambert DLS, transient PERG, and SS PERG, respectively. CONCLUSIONS There is a curvilinear relationship between decibel DLS and both PERG amplitude and neuroretinal rim area, and a linear relationship between 1/Lambert DLS and PERG amplitude and neuroretinal rim area. These findings support the hypothesis that there is no ganglion cell functional reserve but a continuous structure-function relationship, and that the impression of a functional reserve results from the logarithmic (decibel) scaling of the visual field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Responses to chromatic and luminance contrast in glaucoma: a psychophysical and electrophysiological study

Increasing anatomical evidence indicates that large retinal ganglion cells (M-cells) are preferentially damaged in primary open angle glaucoma (OAG), while the smaller ganglion cells (P-cells) are relatively spared. In 13 patients with defined OAG and modest visual field defects, we evaluated the responses to stimuli that are expected to involve primarily the function of the P-pathway and compa...

متن کامل

Electrophysiological and psychophysical flicker sensitivity in patients with primary open-angle glaucoma and ocular hypertension.

Temporal sensitivity was assessed in patients with primary open-angle glaucoma (POAG) and ocular hypertension (OHT). Three measures of flicker sensitivity were obtained: psychophysical modulation thresholds, visual-evoked potentials (VEPs), and focal electroretinograms (FERGs). We found elevated psychophysical thresholds at higher temporal frequencies (30-50 Hz) in patients with POAG, relative ...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Significance of Visual Evoked Potentials in the Assessment of Visual Field Defects in Primary Open-Angle Glaucoma: A Review

Visual evoked potentials is an important visual electrophysiological tool which has been used for the evaluation of visual field defects in primary open-angle glaucoma and is an appropriate objective measure of optic nerve function. Significant correlations between the magnitude of the VEP parameters and MD of Humphrey static perimetry suggest that the impaired visual cortical responses observe...

متن کامل

The Relationship Between Self-Management and Quality of Life and Visual Function in Glaucoma Patients

Introduction: Self-management positively contributes to the Quality of Life of many patients with chronic diseases. Objective: The present study aimed to investigate the relationship between self-management and the quality of life and visual performance among patients with glaucoma. Materials and Methods: The current cross-sectional and comparative study was conducted at the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 43 7  شماره 

صفحات  -

تاریخ انتشار 2002