Use of hypothermia to allow low-tidal-volume ventilation in a patient with ARDS.
نویسندگان
چکیده
Low-tidal-volume ventilation reduces mortality in patients with ARDS, but there are often challenges in implementing lung-protective ventilation, such as acidosis from hypercapnia. In a patient with severe ARDS we achieved adequate ventilation with a very low tidal volume (4 mL/kg ideal body weight) by inducing mild hypothermia (body temperature 35-36°C).
منابع مشابه
PReVENT - protective ventilation in patients without ARDS at start of ventilation: study protocol for a randomized controlled trial
BACKGROUND It is uncertain whether lung-protective mechanical ventilation using low tidal volumes should be used in all critically ill patients, irrespective of the presence of the acute respiratory distress syndrome (ARDS). A low tidal volume strategy includes use of higher respiratory rates, which could be associated with increased sedation needs, a higher incidence of delirium, and an increa...
متن کاملAcute Respiratory Distress Syndrome in a Patient With Suspected Influenza: A Case Report
Acute Respiratory Distress Syndrome (ARDS) is a clinical syndrome consisting of tachypnea, refractory hypoxemia, and diffuse opacities on chest radiographs after infection or trauma which ultimately leads to respiratory failure. The principles of treatment are based on patient care in ICU, mechanical ventilation and medical treatments. By using lower plateau, less tidal volume, higher positive ...
متن کاملCustomization of an open-lung ventilation strategy to treat a case of life-threatening acute respiratory distress syndrome.
The ARDS Network low-tidal-volume protocol is considered the standard of care for patients with acute lung injury (ALI) or acute respiratory distress syndrome (ARDS). The protocol is built on the foundation of low-tidal-volume ventilation, use of a combined PEEP and F(IO(2)) table, and managing alveolar end-inspiratory pressure by limiting the plateau airway pressure to ≤ 30 cm H(2)O. Although ...
متن کاملComputational simulation indicates that moderately high-frequency ventilation can allow safe reduction of tidal volumes and airway pressures in ARDS patients
BACKGROUND A recent prospective trial using porcine models of severe acute respiratory distress syndrome (ARDS) indicated that positive-pressure ventilation delivered by a conventional intensive care ventilator at a moderately high frequency allows safe reduction of tidal volume below 6 ml/kg, leading to more protective ventilation. We aimed to explore whether these results would be replicated ...
متن کاملScience review: Mechanisms of ventilator-induced injury
Acute respiratory distress syndrome (ARDS) and acute lung injury are among the most frequent reasons for intensive care unit admission, accounting for approximately one-third of admissions. Mortality from ARDS has been estimated as high as 70% in some studies. Until recently, however, no targeted therapy had been found to improve patient outcome, including mortality. With the completion of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 56 12 شماره
صفحات -
تاریخ انتشار 2011