The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study.
نویسندگان
چکیده
OBJECTIVES While caution in the use of small-diameter (< or = 3.5 mm) implants has been advocated in view of an increased risk of fatigue fracture under clinical loading conditions, a variety of implant designs with diameters < 3 mm are currently offered in the market for reconstructions including fixed restorations. There is an absence of reported laboratory studies and randomized-controlled clinical trials to demonstrate clinical efficacy for implant designs with small diameters. This laboratory study aimed to provide comparative data on the mechanical performance of a number of narrow commercially marketed implants. MATERIALS AND METHODS Implants of varying designs were investigated under a standardized test set-up similar to that recommended for standardized ISO laboratory testing. Implant assemblies were mounted in acrylic blocks supporting laboratory cast crowns and subjected to 30 degrees off-axis loading on an LRX Tensometer. Continuous output data were collected using Nexygen software. RESULTS Load/displacement curves demonstrated good grouping of samples for each design with elastic deformation up to a point of failure approximating the maximum load value for each sample. The maximum loads for Straumann (control) implants were 989 N (+/-107 N) for the 4.1 mm RN design, and 619 N (+/-50 N) for the 3.3 mm RN implant (an implant known to have a risk of fracture in clinical use). Values for mini implants were recorded as 261 N (+/-31 N) for the HiTec 2.4 mm implant, 237 N (+/-37 N) for the Osteocare 2.8 mm mini and 147 N (+/-25 N) for the Osteocare mini design. Other implant designs were also tested. CONCLUSIONS The diameters of the commercially available implants tested demonstrated a major impact on their ability to withstand load, with those below 3 mm diameter yielding results significantly below a value representing a risk of fracture in clinical practice. The results therefore advocate caution when considering the applicability of implants < or = 3 mm diameter. Standardized fatigue testing is recommended for all commercially available implants.
منابع مشابه
Biomechanical finite element analysis of small diameter and short dental implants: extensive study of commercial implants.
In recent years, mini and short dental implants have become increasingly popular as treatment alternatives for patients in whom the bone is unsuitable for a standard implant. As yet, no detailed scientific analysis of the mechanical and biomechanical impact of the reduced diameter and length of these implants has been published. We analysed 21 commercially available implants (13 mini, eight sho...
متن کاملThe Comparison of Survival Rates between Narrow Diameter Implants and Standard Diameter Implants: An Updated Meta-analysis
Background: One of the key objectives is to update knowledge in order to develop treatment and care recommendations based on research findings. The purpose of the present meta-analysis was to compare the survival rate of narrow dental implants (NDI) with standard dental implants (SDI). Methods: The international databases targeted for conducting a broad search included PubMed (Medline), Sco...
متن کاملPhotoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wide.
PURPOSE This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. MATERIALS AND METHODS Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and ob...
متن کاملEffect of mini-implant length and diameter on primary stability under loading with two force levels.
Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in b...
متن کاملComparison of patient satisfaction with mini-implant versus standard diameter implant overdentures: a systematic review and meta-analysis of randomized controlled trials
Mini-implants have certain advantages over standard size implants which are being tested in various randomized controlled trials. This systematic review and meta-analysis aims to compare conventional implant overdentures to mini-implant-retained overdentures as regards to patient satisfaction. Electronic databases were searched for eligible studies data required were extracted. The extracted da...
متن کاملذخیره در منابع من