OBJECTIVES The purpose of this study was to determine the concordance of the Broselow tape with the measured heights and weights of a community-based population of children, especially in light of the increase in obesity in today's children. METHODS The authors examined more than 7,500 children in a cross-sectional, descriptive study in two different cohorts of children to compare their actual weight with their predicted weight by a color-coded tape measure. RESULTS In all patients, the percent agreement and kappa values of the Broselow color predicted by height versus the actual color by weight for the 2002A tape were 66.2% and 0.61, respectively. The concordance was best in infants, followed by school-age children, toddlers, and preschoolers (kappa = 0.66, 0.44, 0.39, and 0.39, respectively; percent agreement, 81.3%, 58.2%, 60.7%, and 64.0%, respectively). The tapes accurately predicted (within 10%) medication dosages for resuscitation in 55.3%-60.0% of the children. The number of children who were underdosed (by > or =10%) exceeded those who were overdosed (by > or =10%) by 2.5 to 4.4 times (p < 0.05). The tapes accurately predicted uncuffed endotracheal tube sizes when compared with age-based guidelines in 71% of the children, with undersizing (> or =0.5 mm) exceeding oversizing by threefold to fourfold (p < 0.05). CONCLUSIONS The Broselow tape color-coded system inaccurately predicted actual weight in one third of children. Caregivers need to take into consideration the accuracy of this device when estimating children's weight during the resuscitation of a child.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Indian pediatric emergency weight estimation tool: prospective adjustment of the Broselow tape

BACKGROUND This study aims to remodel the Broselow Pediatric Emergency Tape for the Indian pediatric population. The Broselow tape overestimates the heights of the Indian pediatric population and remits inaccurate predicted weights for all color zones with varying degrees and could result in overresuscitation of Indian children in emergency settings. The Indian children are underweight for thei...

متن کامل

A correlation analysis of Broselow™ Pediatric Emergency Tape-determined pediatric weight with actual pediatric weight in India.

BACKGROUND The Broselow™ Pediatric Emergency Tape indicates standardized, pre-calculated medication doses, dose delivery volumes, and equipment sizes using color-coded zones based on height-weight correlations. The present study attempted to provide more evidence on the effectiveness of the Broselow™ Pediatric Emergency Tape by comparing the tape-estimated weights with actual weights. We hypoth...

متن کامل

Validity of Broselow tape for estimating weight of Indian children

BACKGROUND & OBJECTIVES The Broselow tape has been validated in both ambulatory and simulated emergency situations in the United States and is believed to reduce complications arising from inaccurate drug dosing and equipment sizing in paediatric population. This study was conducted to determine the relationship between the actual weight and weight determined by Broselow tape in the Indian chil...

متن کامل

The accuracy of Broselow pediatric emergency tape in estimating body weight of pediatric patients

OBJECTIVES To determine the accuracy of the Broselow tape on estimating body weights of selected Saudi children. Methods: This is prospective study of children aged 7 days to 13 years who attended the Emergency Department of King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Saudi Arabia, from June 2015 to September 2015. Only children less than 34 kg were enrolled fo...

متن کامل

Comparison of Errors Using Two Length-Based Tape Systems for Prehospital Care in Children.

BACKGROUND The use of a length/weight-based tape (LBT) for equipment size and drug dosing for pediatric patients is recommended in a joint statement by multiple national organizations. A new system, known as Handtevy™, allows for rapid determination of critical drug doses without performing calculations. OBJECTIVE To compare two LBT systems for dosing errors and time to medication administrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Academic emergency medicine : official journal of the Society for Academic Emergency Medicine

دوره 13 10  شماره 

صفحات  -

تاریخ انتشار 2006