Phosphated surfactants as pseudostationary phase for micellar electrokinetic chromatography: separation of polycyclic aromatic hydrocarbons.
نویسندگان
چکیده
A double alkyl chain di(2-ethylhexyl)phosphate (DEHP) is introduced as a potential anionic micellar pseudophase for a wide range of benzene derivatives and/or polycyclic aromatic hydrocarbons (PAHs). Several parameters such as concentration of phosphated surfactant, type and concentration of organic solvents (acetonitrile, isopropanol, and methanol), as well as capillary electrophoresis separation voltage were optimized to enhance resolution, efficiency and selectivity as well as to maximize peak capacities. The migration times and selectivity order for a number of PAHs differ significantly, depending on the type of organic solvent added to the DEHP surfactant. Acetonitrile at a concentration of 30% v/v in combination with 100 mM DEHP gave optimum separation for a mixture of 21 benzene derivatives and PAHs in under 16 min.
منابع مشابه
SEPARATION OF POLYCYCLIC AROMATIC HYDROCARBONS WITH MIXED MICELLAR HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
Separation of Polycyclic Aromatic Hydrocarbons was performed by RP-HPLC using mixed micellar mobile phase. Effect of temperature, types and amounts of coorganic solvent in mobile phase on efficiency, asymmetry factor and selectivity factor showed that the appropriate condition for separation of these compounds was 3% isopropanol (V/V) as co-organic solvent in mobile phase at 40°C. Analysis of...
متن کاملPolymeric Anionic Surfactant for Electrokinetic Chromatography: Separation of 16 Priority Polycyclic Aromatic Hydrocarbon Pollutants
Electrokinetic chromatography (EKC) with poly(sodium undecylenic sulfate) (poly-SUS) is utilized to separate environmental pollutants such as 2-6-ring polycyclic aromatic hydrocarbons (PAHs). Parameters such as pH, concentration of polymeric surfactants, and the use of organic modifiers were investigated to follow the retention trends of PAHs. A baseline separation of all 16 PAHs in about 30 mi...
متن کاملPrinciples of micellar electrokinetic capillary chromatography applied in pharmaceutical analysis.
Since its introduction capillary electrophoresis has shown great potential in areas where electrophoretic techniques have rarely been used before, including here the analysis of pharmaceutical substances. The large majority of pharmaceutical substances are neutral from electrophoretic point of view, consequently separations by the classic capillary zone electrophoresis; where separation is base...
متن کاملCharacterization and application of sodium di(2-ethylhexyl) sulfosuccinate and sodium di(2-ethylhexyl) phosphate surfactants as pseudostationary phases in micellar electrokinetic chromatography.
Sodium di(2-ethylhexyl) sulfosuccinate (DOSS) and sodium di(2-ethylhexyl) phosphate (NaDEHP) surfactants, with double alkyl chains and negatively charged headgroups, were characterized using fluorescence quenching, densitometry, and tensiometry techniques to determine their aggregation number, partial specific volume, and critical aggregation concentration. These two surfactants were then appli...
متن کاملMonomeric and polymeric anionic gemini surfactants and mixed surfactant systems in micellar electrokinetic chromatography. Part I: characterization and application as novel pseudostationary phases.
Sodium di(undecenyl) tartarate monomer (SDUT), a vesicle-forming amphiphilic compound possessing two hydrophilic carboxylate head groups and two hydrophobic undecenyl chains gemini surfactant, was prepared and polymerized to form a polymeric gemini surfactant (i.e., poly-SDUT). These anionic surfactant systems with carboxylate (SDUT and poly-SDUT) and sulfate (sodium dodecyl sulfate, SDS) head ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Electrophoresis
دوره 18 2 شماره
صفحات -
تاریخ انتشار 1997