Inter-Instrument Comparison of Bioimpedance Spectroscopic Analysers
نویسنده
چکیده
Three commercially available bioimpedance spectroscopy analysers were compared for technical performance and for their design purpose of prediction of body composition. All three analysers were electronically stable, remaining in calibration over a year, and provided highly reproducible (coefficients of variation < 0.5%) and accurate (within 0.5% of component values) measurements of impedances of a test circuit. Whole body impedances in humans were highly correlated between all three instruments although significant biases between instruments were observed, particularly for the measurement of intracellular resistance. However, when the measured impedances, and using instrument-specific resistivity coefficients, were used to predict fat-free mass of the subjects, the difference between instruments was approximately 1.7 kg fat-free mass, a value comparable with that observed for the error associated with reference methods such as multi-compartment models of body composition. It is concluded that, with appropriate regard to standardisation of measurement protocol, all three analysers are suitable for their design purpose of estimating body composition in humans.
منابع مشابه
Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories.
The aim of this study was to test the hypothesis that differences in oxygen tension (PO2) and carbon dioxide tension (PCO2) values from measurements performed on different blood gas analysers in different laboratories are clinically insignificant. Samples of fresh whole human tonometered blood (PO2 8.1 kPa (60.8 mmHg); PCO2 5.3 kPa (39.9 mmHg)) were placed in airtight glass syringes and transpo...
متن کاملElectronic control in random access analysers
Improvements in microchip technology have produced a new breed of computerized laboratory analysers. Modern analysers have both self-acting and self-regulating mechanisms. Automatic self-checking diagnostics allow preventive service and repair. An instrument can be implemented through changes in software. Chemometrics help to check reagent integrity, validate calibration, and quality control. C...
متن کاملTextile-enabled Bioimpedance Instrumentation for Personalised Health Monitoring Applications
v
متن کاملSelectivity and random-access in automatic analysers
Progress in automation in clinical chemistry hasfeatured in recent years a change from rigid to very flexible instruments. The latest instruments are able to perform on each sample only those tests requested, and often do so in a random sequence. The technological aspects of this progress in instrument design are described in this paper (these include computerization ofanalytical steps, multipl...
متن کاملMean Expected Error in Prediction of Total Body Water: A True Accuracy Comparison between Bioimpedance Spectroscopy and Single Frequency Regression Equations
For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer t...