A Dedicated Low-Cost Fluorescence Microfluidic Device Reader for Point- of-Care Ocular Diagnostics
نویسندگان
چکیده
Microfluidic fluorescence assay devices show great promise as preclinical and clinical diagnostic instruments. Normally, fluorescence signals from microfluidic chips are quantified by analysis of images obtained with a commercial fluorescence microscope. This method is unnecessarily expensive, time consuming, and requires significant operator training, particularly when considering future clinical translation of the technology. In this work, we developed a dedicated low cost fluorescence microfluidic device reader (FMDR) to read sandwich immunofluorescence assay (sIFA) devices configured to detect vascular endothelial growth factor ligand concentrations in ocular fluid samples. Using a series of sIFA calibration standards and a limited set of human ocular fluid samples, we demonstrated that our FMDR reader has similar sensitivity and accuracy to a fluorescence microscope for this task, with significantly lower total cost and reduced reading time. We anticipate that the reader could be used with minor modifications for virtually any fluorescence microfluidic device. [DOI: 10.1115/1.4023995]
منابع مشابه
Development of a Microfluidic Fluorescence Immunosensor for Point-of-Care Diagnostics
The miniaturization of conventional immunoassays using microfluidic techniques has proven promising in bringing accurate and quantitative clinical diagnosis to the point-of-care (POC). However, the microfluidics community has yet to produce many commercial devices for such applications. The main reason for this is the difficulty in producing low-cost, rapid, sensitive, automated, and portable i...
متن کاملLow-cost bioanalysis on paper-based and its hybrid microfluidic platforms.
Low-cost assays have broad applications ranging from human health diagnostics and food safety inspection to environmental analysis. Hence, low-cost assays are especially attractive for rural areas and developing countries, where financial resources are limited. Recently, paper-based microfluidic devices have emerged as a low-cost platform which greatly accelerates the point of care (POC) analys...
متن کاملA Handheld Point-of-Care Genomic Diagnostic System
The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-power...
متن کاملA centrifugal microfluidic platform for point-of-care diagnostic applications
Microfluidic systems enable precise control over tiny volumes of fluid in a compact and low-cost form, thus providing the ideal platform on which to develop point-of-care diagnostic solutions. Centrifugal microfluidic systems, also referred to as lab-on-a-disc or lab-on-a-CD systems, provide a particularly attractive solution for the implementation of microfluidic point-of-care diagnostic solut...
متن کاملPaper-based microfluidic system for tear electrolyte analysis† †We declare no competing financial interests. ‡ ‡Electronic supplementary information (ESI) available: Microscopic images of G1 paper and G41 paper under brightfield; optimization of CO2 laser radiation fluence and beam speed for ablating filter paper-G1; photographs of DI water diffusion in microfluidic channels with different lengths, different widths, different viscosities of fluid and different numbers of channels; fluorescence intensity readouts of Na+ and K+ ions with varied concentrations of fluorescent probes; effect of variations in temperature on fluorescence intensity; photographs of DMSO on G1 paper dried in the air; calibration curves of electrolyte sensing on G1 paper using microplate reader measurement; calculation of sensitivity of the fluorescent sensors based on International Union of Pure and Applied Chemistry (IUPAC) guidelines; quantification of ion interference in buffer solution and artificial tear fluid; light attenuation of LED lights using different optical filters; the design of the sample collection device and its potential clinical use; calibration curves of electrolyte sensors using the paper-based microfluidic system; quantifications of evaporation effect on sampling process; design of the sample collection device and its potential clinical use; batch-to-batch variation experiments; equation for background subtraction; movies of sample collection and measurements. See DOI: 10.1039/c6lc01450j Click here for additional data file. Click here for additional data file. Click here for additional data file. Click here for additional data file.
The analysis of tear constituents at point-of-care settings has a potential for early diagnosis of ocular disorders such as dry eye disease, low-cost screening, and surveillance of at-risk subjects. However, current minimally-invasive rapid tear analysis systems for point-of-care settings have been limited to assessment of osmolarity or inflammatory markers and cannot differentiate between dry ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013