Dialysis water treated by reverse osmosis decreases the levels of C-reactive protein in uremic patients.
نویسندگان
چکیده
Atherosclerosis is a major complication of chronic renal failure. Microinflammation is involved in atherogenesis and is associated with uremia and dialysis. The role of dialysate water contamination in inducing inflammation has been debated. Our aim was to study inflammatory markers in patients on chronic dialysis, before and 3 to 6 months after switching the water purification system from deionization to reverse osmosis. Patients had demographic, clinical and nutritional information collected and blood drawn for determination of albumin, ferritin, C-reactive protein (CRP), interleukin-6, and tumor necrosis factor-alpha in both situations. Acceptable levels of water purity were less than 200 colony-forming units of bacteria and less than 1 ng/ml of endotoxin. Sixteen patients died. They had higher median CRP (26.6 vs 11.2 mg/dl, P = 0.007) and lower median albumin levels (3.1 vs 3.9 g/l, P < 0.05) compared to the 31 survivors. Eight patients were excluded because of obvious inflammatory conditions. From the 23 remaining patients (mean age +/- SD: 51.3 +/- 13.9 years), 18 had a decrease in CRP after the water treatment system was changed. Overall, median CRP was lower with reverse osmosis than with deionization (13.2 vs 4.5 mg/l, P = 0.022, N = 23). There was no difference in albumin, cytokines, subjective global evaluation, or clinical and biochemical parameters. In conclusion, uremic patients presented a clinically significant reduction in CRP levels when dialysate water purification system switched from deionization to reverse osmosis. It is possible that better water treatments induce less inflammation and eventually less atherosclerosis in hemodialysis patients.
منابع مشابه
بررسی کارایی سیستم اسمز معکوس در حذف سرب، کادمیوم، کروم و روی از آب ورودی به دستگاه های دیالیز بیمارستان های استان کرمانشاه
Background and purpose: The chemical quality of feed water to dialysis instrument is very important, especially in terms of heavy metals which could cause serious health problems for dialysis patients. This study aimed to determine the concentration of selected heavy metals (lead, cadmium, chromium and zinc) in feed water to dialysis instrument and compared that with EPH and AAMI standards in h...
متن کاملReuse of Refinery Treated Wastewater in Cooling Towers
In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure differ...
متن کاملبررسی خارش اورمیک و عوامل مرتبط با آن در بیماران همودیالیزی
Background and Objective: Although uremic pruritus (UP) is one of the most common disabling problems in hemodialysis (HD) patients, its associated factors have remained unknown. The purpose of this study was to evaluate the prevalence and severity of UP in a group of Iranian hemodialysis patients and its associated clinical and laboratory factors. Materials and Methods: This cross-sectional ...
متن کاملبررسی شاخصهای میکروبی و شیمیایی آب مورداستفاده در دستگاههای دیالیز بیمارستان شهید بهشتی قروه
Background and Objectives: Each patient has renal failure in any dialysis with high water volume, which is in direct contact with the patient's blood. The presence of any chemical and microbial contamination in water used in homodynamic devices can be very dangerous for these patients. The purpose of this study was to determine the efficiency of reverse osmosis open systems in improving the wat...
متن کاملMicrobiology of water and fluids for hemodialysis.
In hemodialysis, huge amounts of water are used for diluting the concentrates to produce dialysis fluid. The water is produced on site by reverse osmosis units. The chemical and microbiological quality of the water is essential for dialysis patients. Reverse osmosis units produce water of acceptable chemical quality that can be kept throughout the water system. The microbiological water quality...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas
دوره 38 5 شماره
صفحات -
تاریخ انتشار 2005