3D heterogeneous dose distributions for total body irradiation patients
نویسندگان
چکیده
One major objective of total body irradiation (TBI) treatments is to deliver a uniform dose in the entire body of the patient. Looking at 3D dose distributions for constant speed (CstSpeed) and variable speed (VarSpeed) translating couch TBI treatments, dose uniformity and the effect of body heterogeneities were evaluated. This study was based on retrospective dose calculations of 10 patients treated with a translating couch TBI technique. Dose distributions for CstSpeed and VarSpeed TBI treatments have been computed with Pinnacle3 treatment planning system in homogeneous (Homo) and heterogeneous (Hetero) dose calculation modes. A specific beam model was implemented in Pinnacle3 to allow an accurate dose calculation adapted for TBI special aspects. Better dose coverages were obtained with Homo/VarSpeed treatments compared to Homo/CstSpeed cases including smaller overdosage areas. Large differences between CstSpeed and VarSpeed dose calculations were observed in the brain, spleen, arms, legs, and lateral parts of the abdomen (differences between V100% mean values up to 57.5%). Results also showed that dose distributions for patients treated with CstSpeed TBI greatly depend on the patient morphology, especially for pediatric and overweight cases. Looking at heterogeneous dose calculations, underdosages (2%-5%) were found in high-density regions (e.g., bones), while overdosages (5%-15%) were found in low-density regions (e.g., lungs). Overall, Homo/CstSpeed and Hetero/VarSpeed dose distributions showed more hot spots than Homo/VarSpeed and were greatly dependent on patient anatomy. CstSpeed TBI treatments allow a simple optimization process but lead to less dose uniformity due to the patient anatomy. VarSpeed TBI treatments require more complex dose optimization, but lead to a better dose uniformity independent of the patient morphology. Finally, this study showed that heterogeneities should be considered in dose calculations in order to obtain a better optimization and, therefore, to improve dose uniformity.
منابع مشابه
AbstractID: 13162 Title: 3D heterogeneous dose distributions for Total Body Irradiation Patients
ID: 13162 Title: 3D heterogeneous dose distributions for Total Body Irradiation Patients Purpose: One major objective of Total Body Irradiation (TBI) treatments is to deliver a uniform dose in the entire body of the patient. Looking at 3D dose distributions for constant speed (CteSpeed) and variable speed (VarSpeed) translating couch TBI treatments, dose uniformity and the effect of body hetero...
متن کاملElectron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel
Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...
متن کاملReview of techniques for improving the uniformity of dose distribution in total body irradiation (TBI) with parallel – opposed anterior and posterior geometry
Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two co...
متن کاملComparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation
Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...
متن کاملبکارگیری دزیمتر ژل پلیمر نورموکسیک MAGIC در دزیمتری باریکه الکترون در فانتوم لایهای همگن
Background & Aim: Nowadays, radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Polymer gel dosimeters consist of an aqueous mixture of monomers and a gelling agent, which after irradiation, 3D dose distribution is acquired by using imaging techniques. The aim of this study is to evaluate the application and capability of normoxic polym...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -