Analysis of BOLD fMRI Signal Preprocessing Pipeline on Different Datasets while Reducing False Positive Rates

نویسندگان

  • Yunxiang Ge
  • Yu Pan
  • Weibei Dou
چکیده

The technology of functional Magnetic Resonance Imaging (fMRI) based on Blood Oxygen Level Dependent (BOLD) signal has been widely used in clinical treatments and brain function researches. The BOLD signal has to be preprocessed before being analyzed using either functional connectivity measurements or statistical methods. Current researches show that data preprocessing steps may influence the results of analysis, yet there is no consensus on preprocessing method. In this paper, an evaluation method is proposed for analyzing the preprocessing pipeline of resting state BOLD fMRI (rsBOLD fMRI) data under putative task experiment designs to cast some lights on the preprocessing stage, covering both first and second level analysis. The choices of preprocessing parameters and steps are altered to investigate preprocessing pipelines while observing statistical analysis results, trying to reduce false positives as reported by Eklund et al. in their 2016 PNAS paper. All of the experiment data are separated into 7 datasets, consisting of 220 healthy control samples and 136 patient data that are from 38 incomplete Spinal Cord Injury (SCI) patients and 16 Cerebral Stroke (CS) patients, including multiple scans of some patients at different time. These data were acquired from two different MRI scanners, which may cause difference in analysis results. The evaluation result shows that it has little effect to change parameters in each steps of the classical preprocessing pipeline, which consists head motion correction, normalization and smoothing. Removing time points and the following detrend step can reduce false positives. However, covariates regression and filtering has complicated effects on the data. Note that for single subject analysis, false positives declined consistently after filtering. The result of patient data and healthy controls data which are scanned under the same machine with the same acquisition protocol shows little difference. Yet data acquired with different scanner and protocol influences statistical analysis significantly. As a result, future research should pay more attention on the scanning machine and protocol used. This research is a preliminary investigation on rs-BOLD fMRI signal preprocessing. We hope the conclusions can be of value for other studies in the field of brain function research.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

Combined MEG and fMRI model

An integrated model for magnetoencephalography (MEG) and functional Magnetic Resonance Imaging (fMRI) is proposed. In the proposed model, MEG and fMRI outputs are related to the corresponding aspects of neural activities in a voxel. Post synaptic potentials (PSPs) and action potentials (APs) are two main signals generated by neural activities. In the model, both of MEG and fMRI are related to t...

متن کامل

An Automated, Adaptive Framework for Optimizing Preprocessing Pipelines in Task-Based Functional MRI

BOLD fMRI is sensitive to blood-oxygenation changes correlated with brain function; however, it is limited by relatively weak signal and significant noise confounds. Many preprocessing algorithms have been developed to control noise and improve signal detection in fMRI. Although the chosen set of preprocessing and analysis steps (the "pipeline") significantly affects signal detection, pipelines...

متن کامل

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

Empirical Analyses of BOLD fMRI Statistics

In the companion to this paper (E. Zarahn, G. K. Aguirre, and M. D’Esposito, 1997, NeuroImage, 000– 000), we describe an implementation of a general linear model for autocorrelated observations in which the voxel-wise false-positive rates in fMRI ‘‘noise’’ datasets were stabilized and brought close to theoretical values. Here, implementations of the model are tested for use with statistical par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017