MRI following UKA: The component-bone interface.

نویسندگان

  • Dominik Malcherczyk
  • Jens Figiel
  • Ulrike Hähnlein
  • Susanne Fuchs-Winkelmann
  • Turgay Efe
  • Thomas J Heyse
چکیده

BACKGROUND Loosening is one of the major long-term failure modes in unicondylar knee arthroplasty (UKA). The aim of the study is to describe and characterize implant-bone interface of femoral and tibial components after UKA by means of magnet resonance imaging (MRI). MATERIAL AND METHODS MRI tailored to reduce metallic artefact of the knee after medial UKA was performed in 10 patients as a pilot study. The component-bone interface at femoral and tibial components was evaluated by two independent investigators. They gave degree of confidence to their evaluation of each parameter on a five-point scale. Inter-observer reliability was determined. RESULTS Artefacts provoked by the implants were rare. Inter-observer reliability and confidence were excellent for the femoral interface. They were lower at the tibial interface but results were still satisfactory. CONCLUSIONS Tailored MRI allows reproducible analysis of the component-bone interface after UKA. It is helpful in assessment of suspected loosening after UKA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of surgical indication for knee arthroplasty by cartilage analysis in three compartments using data from Osteoarthritis Initiative (OAI)

BACKGROUND Bicompartmental or unicompartmental knee arthroplasty (BKA, UKA) is currently advocated as an alternative solution to conventional total knee arthroplasty (TKA) in order to preserve bone stock and ligaments for limited osteoarthritis (OA) with intact anterior and posterior cruciate ligaments (ACL, PCL). However, the actual rate of UKA or BKA compared to TKA procedures in OA patients ...

متن کامل

Early failure with massive metallosis and posteromedial wear following atraumatic anterior cruciate ligament rupture after medial unicompartmental knee arthroplasty

Severe metallosis following medial unicompartmental knee arthroplasty (UKA) is relatively rare. It is usually due to long-standing wear of the polyethylene component, resulting in frictional wear between the femoral and tibial metallic components. Biomechanical and cadaveric studies have shown the effects of anterior cruciate ligament (ACL) transection following medial UKA. We describe a case o...

متن کامل

Analysis of an early intervention tibial component for medial osteoarthritis.

Tibial component loosening is an important failure mode in unicompartmental knee arthroplasty (UKA) which may be due to the 6-8 mm of bone resection required. To address component loosening and fixation, a new early intervention (EI) design is proposed which reverses the traditional material scheme between femoral and tibial components. The EI design consists of a plastic inlay for the distal f...

متن کامل

Finite Element Analysis of Mobile-bearing Unicompartmental Knee Arthroplasty: The Influence of Tibial Component Coronal Alignment.

BACKGROUND Controversies about the rational positioning of the tibial component in unicompartmental knee arthroplasty (UKA) still exist. Previous finite element (FE) studies were rare, and the results varied. This FE study aimed to analyze the influence of the tibial component coronal alignment on knee biomechanics in mobile-bearing UKA and find a ration range of inclination angles. METHODS A...

متن کامل

Inaccurate rotational component position in image-free navigated unicompartmental knee arthroplasty

Background/Objective The success of unicompartmental knee arthroplasty (UKA) is highly dependent on the accuracy of component and leg alignment. Computer-assisted surgery is gaining popularity in total knee arthroplasty with numerous studies reporting improved accuracy and decreased variability in implant position and postoperative limb alignment compared with conventional techniques. However, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 81 1  شماره 

صفحات  -

تاریخ انتشار 2015