The reliability of parafoveal cone density measurements
نویسندگان
چکیده
BACKGROUND Adaptive optics scanning light ophthalmoscopy (AOSLO) enables direct visualisation of the cone mosaic, with metrics such as cone density and cell spacing used to assess the integrity or health of the mosaic. Here we examined the interobserver and inter-instrument reliability of cone density measurements. METHODS For the interobserver reliability study, 30 subjects with no vision-limiting pathology were imaged. Three image sequences were acquired at a single parafoveal location and aligned to ensure that the three images were from the same retinal location. Ten observers used a semiautomated algorithm to identify the cones in each image, and this was repeated three times for each image. To assess inter-instrument reliability, 20 subjects were imaged at eight parafoveal locations on one AOSLO, followed by the same set of locations on the second AOSLO. A single observer manually aligned the pairs of images and used the semiautomated algorithm to identify the cones in each image. RESULTS Based on a factorial study design model and a variance components model, the interobserver study's largest contribution to variability was the subject (95.72%) while the observer's contribution was only 1.03%. For the inter-instrument study, an average cone density intraclass correlation coefficient (ICC) of between 0.931 and 0.975 was calculated. CONCLUSIONS With the AOSLOs used here, reliable cone density measurements can be obtained between observers and between instruments. Additional work is needed to determine how these results vary with differences in image quality.
منابع مشابه
Eccentricity dependent changes of density, spacing and packing arrangement of parafoveal cones.
PURPOSE To investigate the distribution of cone density and spacing as well as the preferred packing arrangement of the cone mosaic as a function of retinal eccentricity. METHODS An adaptive optics retinal camera (rtx1, www.imagine-eyes.com) was used to obtain images of the parafoveal cone mosaic in nineteen healthy volunteers. Cone density and spacing were estimated for each subject (both ey...
متن کاملRepeatability of in vivo parafoveal cone density and spacing measurements.
PURPOSE To assess the repeatability and measurement error associated with cone density and nearest neighbor distance (NND) estimates in images of the parafoveal cone mosaic obtained with an adaptive optics scanning light ophthalmoscope (AOSLO). METHODS Twenty-one participants with no known ocular pathology were recruited. Four retinal locations, approximately 0.65° eccentricity from the cente...
متن کاملVariability in parafoveal cone mosaic in normal trichromatic individuals
Parafoveal function is important for daily visual tasks such as reading. Here the variability in cone density along the four cardinal meridians in parafoveal regions of the retina was investigated in vivo using an adaptive optics fundus camera. Ten healthy normal trichromatic individuals were included in the study. There were significant differences in cone density between individuals at all fo...
متن کاملComparing mfERGs with estimates of cone density from in vivo imaging of the photoreceptor mosaic using a modified Heidelberg retina tomograph
The spatial variation in central retinal function determined from mfERG was compared to co-localised measurements of cone density in two normal subjects. Individual cone cells in the parafoveal region of the retina were identified from 1 degrees x1 degrees images of the photoreceptor mosaic using a modified Heidelberg retina tomograph (HRT). The variation in cone density compared well with prev...
متن کاملInterocular symmetry of parafoveal photoreceptor cone density distribution.
PURPOSE To investigate the variation and symmetry of cone density distribution along the nasal and temporal retina of fellow eyes. METHODS An adaptive optics retinal camera (rtx1; Imagine Eyes) was used to obtain images of the parafoveal cone mosaic in 20 healthy subjects. Cone density was estimated at 250, 420, 760, and 1,300 μm eccentricity from the fovea along the nasal and temporal retina...