Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise.

نویسندگان

  • P J Basser
  • S Pajevic
چکیده

This work helps elucidate how background noise introduces statistical artifacts in the distribution of the sorted eigenvalues and eigenvectors in diffusion tensor MRI (DT-MRI) data. Although it was known that sorting eigenvalues (principal diffusivities) by magnitude introduces a bias in their sample mean within a homogeneous region of interest (ROI), here it is shown that magnitude sorting also introduces a significant bias in the variance of the sample mean eigenvalues. New methods are presented to calculate the mean and variance of the eigenvectors of the diffusion tensor, based on a dyadic tensor representation of eigenvalue-eigenvector pairs. Based on their use it is shown that sorting eigenvalues by magnitude also introduces a bias in the mean and the variance of the sample eigenvectors (principal directions). This required the development of new methods to calculate the mean and variance of the eigenvectors of the diffusion tensor, based on a dyadic tensor representation of eigenvalue-eigenvector pairs. Moreover, a new approach is proposed to order these pairs within an ROI. To do this, a correspondence between each principal axis of the diffusion ellipsoid, an eigenvalue-eigenvector pair, and a dyadic tensor constructed from it is exploited. A measure of overlap between principal axes of diffusion ellipsoids in different voxels is defined that employs projections between these dyadic tensors. The optimal eigenvalue assignment within an ROI maximizes this overlap. Bias in the estimate of the mean and of the variance of the eigenvalues and of their corresponding eigenvectors is reduced in DT-MRI experiments and in Monte Carlo simulations of such experiments. Improvement is most significant in isotropic regions, but some is also observed in anisotropic regions. This statistical framework should enhance our ability to characterize microstructure and architecture of healthy tissue, and help to assess its changes in development, disease, and degeneration. Mitigating these artifacts should also improve the characterization of diffusion anisotropy and the elucidation of fiber-tract trajectories in the brain and in other fibrous tissues. Magn Reson Med 44:41-50, 2000. Published 2000 Wiley-Liss, Inc.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parametric and non-parametric statistical analysis of DT-MRI data.

In this work parametric and non-parametric statistical methods are proposed to analyze Diffusion Tensor Magnetic Resonance Imaging (DT-MRI) data. A Multivariate Normal Distribution is proposed as a parametric statistical model of diffusion tensor data when magnitude MR images contain no artifacts other than Johnson noise. We test this model using Monte Carlo (MC) simulations of DT-MRI experimen...

متن کامل

Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review.

This article treats the theoretical underpinnings of diffusion-tensor magnetic resonance imaging (DT-MRI), as well as experimental design and data analysis issues. We review the mathematical model underlying DT-MRI, discuss the quantitative parameters that are derived from the measured effective diffusion tensor, and describe artifacts that arise in typical DT-MRI acquisitions. We also discuss ...

متن کامل

Dealing with Uncertainty in Diffusion Tensor MR Data

This paper explains how radio frequency (RF) background noise produces uncertainty in measured diffusion tensor MRI (DT-MRI) data, how this noise can be modeled, and how its effects can be mitigated. DT-MRI data are derived from a series of magnitude diffusion-weighted images (DWI) in which RF noise is rectified. A new Gaussian distribution is proposed that describes the variability of the esti...

متن کامل

DT-MRI Tractography and its Application in Cognitive Neuroscience

Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...

متن کامل

DT-MRI Tractography and its Application in Cognitive Neuroscience

Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 2000