Low-dose computed tomography of the abdomen and lumbar spine

نویسندگان

  • Muhammed Alshamari
  • Seppo Koskinen
چکیده

Muhammed Alshamari (2016): Low-dose computed tomography of the abdomen and lumbar spine. Örebro Studies in Medicine 137. Radiography is a common radiologic investigation despite abundant evidence of its limited diagnostic value. On the other hand, computed tomography (CT) has a high diagnostic value and is widely considered to be among the most important advances in medicine. However, CT exposes patients to a higher radiation dose and it might therefore not be acceptable simply to replace radiography with CT, despite the powerful diagnostic value of this technique. At the expense of reduced CT image quality, which could be adjusted to the diagnostic needs, low-dose CT of abdomen and lumbar spine can be performed at similar dose to radiography. The aim of the current thesis project was to evaluate low-dose CT of the abdomen and lumbar spine and to compare it with radiography. The hypothesis was that CT would give better image quality and diagnostic information compared to radiography at similar dose levels. Firstly, the diagnostic accuracy of low-dose CT of the abdomen was evaluated. Results showed that low-dose CT of abdomen has a high sensitivity and specificity compared to radiography, i.e., it has higher diagnostic accuracy. Similar results were obtained from our systematic review. Secondly, in a phantom study, an ovine phantom was scanned at various CT settings. The image quality was evaluated to obtain a protocol for the optimal settings for low-dose CT of lumbar spine at 1 mSv. This new protocol was then used in a clinical study to assess the image quality of low-dose CT of the lumbar spine and compare it to radiography. Results showed that low-dose CT has significantly better image quality than radiography. Finally, the impact of Iterative reconstruction (IR) on image quality of lumbar spine CT was tested. Iterative reconstruction is a recent CT technique aimed to reduce radiation dose and/or improve image quality. The results showed that the use of medium strength IR levels in the reconstruction of CT image improves image quality compared to filtered back projection. In conclusion, low-dose CT of the abdomen and lumbar spine, at about 1 mSv, has better image quality and gives diagnostic information compared to radiography at similar dose levels and it could therefore replace radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Entrance skin dose assessment of selected computed radiography facilities in Ghana

Background: The basic challenge with computed radiography (CR) systems is the large dynamic range which provides an opportunity for radiographers to gradually increase exposure factors and still produce good image quality, a practice that can lead to dose creep. Materials and Methods: The aim of this study was to establish  the entrance skin dose (ESD) values for nine selected examinations in t...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality.

BACKGROUND Lumbar spine radiography has limited diagnostic value but low radiation dose compared with computed tomography (CT). The average effective radiation dose from lumbar spine radiography is about 1.1 mSv. Low-dose lumbar spine CT may be an alternative to increase the diagnostic value at low radiation dose, around 1 mSv. PURPOSE To determine the optimal settings for low-dose lumbar spi...

متن کامل

ارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی

Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&rsquo...

متن کامل

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016