Clinical study of the laser sheath for lead extraction: the total experience in the United States.

نویسندگان

  • Charles L Byrd
  • Bruce L Wilkoff
  • Charles J Love
  • T Duncan Sellers
  • Christopher Reiser
چکیده

The laser sheath uses optical fibers, delivering pulsed ultraviolet excimer laser light, to vaporize fibrotic tissue binding intravenous cardiac leads to the vein or heart wall during lead extraction from the implant vein. The total investigational experience with laser sheaths is reported. During the period from October 1995 to December 1999, 2,561 pacing and defibrillator leads were treated in 1,684 patients at 89 sites in the United States with three sizes of laser sheath. Endpoints were complete removal of the lead, partial removal (leaving the tip behind), or failure (abandoning the lead, onset of complications, change to transfemoral or transatrial approach). Minimal follow-up at 30 days was recorded. Of the leads, 90% were completely removed, 3% were partially removed, and the balance were failures. Major perioperative complications (tamponade, hemothorax, pulmonary embolism, lead migration, and death) were observed in 1.9% of patients with in hospital death in 13 (0.8%). Minor complications were seen in an additional 1.4% of patients. Multivariate analysis showed that implant duration was the only preoperative independent predictor of failure; female sex was the only multivariate predictor of complications. Success and complications were not dependent on laser sheath size. At follow-up, various extraction related complications were observed in 2% of patients. The learning curve showed a trend toward fewer complications with experience. Lead extraction with the laser sheath can be safely practiced with high success rates. Success is independent of laser sheath size. Major complications can be expected in < 2% of patients, and occur more often during an investigator's early experience.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Public Spending on Health Service and Policy Research in Canada, the United Kingdom, and the United States: A Modest Proposal

Health services and policy research (HSPR) represent a multidisciplinary field which integrates knowledge from health economics, health policy, health technology assessment, epidemiology, political science among other fields, to evaluate decisions in health service delivery. Health service decisions are informed by evidence at the clinical, organizational, and policy level, levels with distinct...

متن کامل

Comparing Mental and Physical Health of Full-Service Sex Workers in the United States to the Health of the General Population in 2019-2020

Introduction: Full-service sex workers (FSSWs) are relatively prevalent in the U.S. and are known to face criminalization, stigma, and other factors relating to poor health. The main aim of this study was compare the mental and physical health of full-service sex workers in the United States in 2019-2020 Methods: In this prospective cohort study, participants were recruited through national c...

متن کامل

Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial.

OBJECTIVES The purpose of this study was to evaluate the safety and effectiveness of pacemaker lead extraction with the excimer sheath in comparison to nonlaser lead extraction. BACKGROUND Fibrotic attachments that develop between chronically implanted pacemaker leads and to the venous, valvular and cardiac structures are the major obstacles to safe and consistent lead extraction. Locking sty...

متن کامل

Initial experience in the extraction of chronically implanted pacemaker leads using the Excimer laser sheath.

OBJECTIVE To assess the safety and efficiency of the Excimer laser sheath in extracting chronically implanted pacemaker leads. PATIENTS Eight patients were studied (one female, mean age 62 years, range 34 to 77) with 17 pacemaker leads (five atrial, 10 ventricular, two implantable defibrillator). The mean implantation time was 65 months (range 23 to 188). The indications for lead extraction w...

متن کامل

Laser-assisted lead extraction: the European experience.

AIMS The aim of this study is to investigate the safety and effectiveness of Excimer laser-assisted lead extraction in Europe. The final European multi-centre study experience is presented. METHOD AND RESULTS The Excimer is a cool cutting laser (50 degrees C) with a wavelength of 308 nm. The energy is emitted from the tip of a flexible sheath and is absorbed by proteins and lipids, 64% of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 25 5  شماره 

صفحات  -

تاریخ انتشار 2002