Kinetic aspects of cyanmethemoglobin formation from carboxyhemoglobin.

نویسنده

  • F L Rodkey
چکیده

The conversionof carboxyhemoglobin(H bCO) to cyanmethemoglobin (M HbCN) by Drabkin’s reagent has been shown to be considerablyslower than is the same reaction with oxyhemoglobin(Hb02). Conversionof Hb02 to MHbCN is complete in 10 mm. whereas total conversionof HbCO requires 90-120 mm. This difference in reaction rate must be consideredin the determination of total hemoglobinas MHbCN when the blood contains appreciable HbCO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of carboxyhemoglobin and total hemoglobin by five specialized spectrophotometers (CO-oximeters) in comparison with reference methods.

We measured total hemoglobin (CtHb) and carboxyhemoglobin (COHb) in 100 patients' blood samples by using five specialized spectrophotometers (CO-oximeters)--IL 482 CO-Oximeter, Corning 2500 CO-oximeter, Radiometer OSM 3 Hemoximeter, Corning 270 CO-oximeter, and the AVL 912 CO-Oxylite--and compared the results with those obtained with the manual cyanmethemoglobin method and a gas-chromatographic...

متن کامل

Kinetic Aspects of Tetrahydrobenzo[b]pyran Formation in the Presence of Fructose as a Green Catalyst: a Mechanistic Investigation

The kinetics and mechanism of the reaction between benzaldehyde 1, malononitrile 2 and dimedone 3 in a mixture of ethanol and water as solvents in the presence of fructose as a biodegradable catalyst has been studied by the spectroscopic method (UV-Vis spectrophotometry method). The influence of various parameters (temperature, solvent and concentration) was studied on the reaction by means of ...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

A Source of Error in the Cyanmethemoglobin Method of Determination of Hemoglobin Concentration in Blood Containing Carbon Monoxide.

The necessity of determining the total hemoglobin concentration in blood containing sublethal and lethal concentrations of carbonmonoxyhemoglobin* prompted a search of the literature to ascertain if the cyanmcthemoglobin method would be acceptable. In several recent articles it was stated that carbonmonoxyhemoglobin could be so determined, but the analytical details were not described.' "• Cros...

متن کامل

The effect of mechanical activation on the kinetic and formation mechanism of a niobium aluminide based nanocomposite

In this paper the feasibility of NbAl3/Al2O3 nanocomposite formation through mechanochemical reaction between Al and Nb2O5 and the effect of mechanical activation on the kinetic and reaction mechanism were investigated. Structural and phase evolution during mechanical alloying were studied by employing transmission electron microscopy (TEM)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 1967