Use of polyethylene glycol in separating bound from unbound ligand in radioimmunoassay of thyroxine.
نویسندگان
چکیده
In most rapid radioimmunoassay methods, absorbents are used that disturb the equilibrium of the ligand-antibody interaction; thus the separation process must be rigidly timed. We show here that polyethylene glycol (mol wt. 6000) abolishes this constant. We measured gamma-globulin precipitation by polyethylene glycol (150g/liter) in a thyroxine radioimmunoassay system involving use of a sheep anti-thyroxine antiserum, quantitatively and qualitatively, with either normal human serum or completely precipitated at pH 6-9 at 4 and 25 degrees C, but incompletely if salt concentration was high (1 mol/liter). Specificity of gamma-globulin precipitation increased with increasing pH and temperature. All gamma-globulin-bound thyroxine was precipitated, and also some not bound to gamma-globulin. This was taken into account by including "blank" tubes (no antibody, but with normal sheep serum) in all assays. Because this reaction is predominantly entropic and temperature independent, the entire procedure can be done at 37 degrees C and room temperature without rigid timing. The assay requires 10 mul of serum, its reproducibility is 4-8% (CV) in the euthyroid and hyperthyroid range, and its accuracy is close to 100%.
منابع مشابه
Assessment of a method for measuring serum thyroxine by radioimmunoassay, with use of polyethylene glycol precipitation.
We assessed the efficacy of a new thyroxine radioimmunoassay kit (Abott) in which polyethylene glycol is used to separate bound from free hormone. Mean serum thyroxine was 88 +/- 15 (+/-SD) microgram/liter for 96 normal persons. Results for hypothyroid and hyperthyroid persons were clearly separated from those for normal individuals. Women taking oral contraceptive preparations showed variable ...
متن کاملRapid radioimmunoassay of triiodothyronine.
The method used in this report is based on the immunological production of a specific antisera to tnlodothyronine (T3) in rabbits. Conducted at 4 #{176}C, the radioimmunoassay requires three to five days to complete. Hoping to speed this assay, we investigated the influence of time, temperature, and pH. Incubation at 37 #{176}C and pH 8.0 for 30 mm did not deleteriously affect either precision,...
متن کاملRadioimmunoassay of plasma testosterone, with use of polyethylene glycol to separate antibody-bound and free hormone.
We have developed a reliable radioimmunoassay for testosterone in plasma, polyethylene glycol ("Carbowax 6000") being used to separate antibody-bound and free hormone. Testosteron is separated from interfering steroids, notably dihydrotestosterone, by liquid-liquid partition chromatography on infusorial earth (Celite). The assay is sensitive (9 pg for standards), precise, and accurate. The lowe...
متن کاملColumn affinity chromatography for bound/free separation in ligand assays. I. Radioimmunoassay of choriomammotropin (human placental lactogen).
A method is described for separating antibody-bound from free fractions in ligand assays by column affinity chromatography, and its application to radioimmunoassay of choriomammotropin. In the method, 70 x 10 mm (i.d.) polypropylene columns containing about 150 mg of immunosorbent (goat anti-rabbit gamma-globulins covalently linked to Sepharose CL-4B) are used. Standards or unknowns, tracer and...
متن کاملIntroduction of a rapid, simple radioimmunoassay and quality control scheme for thyroxine.
A simple radioimmunoassay has been developed for service purposes to determine serum total thyroxine levels. Only three additions are required, of standard or sample, labelled thyroxine and antibody in polyethylene glycol. After 2 hours' incubation at room temperature the antibody-bound and free fractions are separated by centrifugation. Serum total thyroxine levels were measured in 195 euthyro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 22 3 شماره
صفحات -
تاریخ انتشار 1976