Single Beat Determination of Intraventricular Systolic Dyssynchrony in Patients with Atrial Fibrillation and Systolic Dysfunction.

نویسندگان

  • Anita Sadeghpour
  • Alireza Hoghooghi
  • Zahra Alizadehsani
  • Mohsen Rezaei
  • Sevil Aghapour
  • Majid Haghjoo
چکیده

BACKGROUND Atrial fibrillation (AF) is the most common clinically significant cardiac arrhythmia. However, diagnosis of intraventricular dyssynchrony in patients with AF is difficult due to beat-to-beat variation. Additionally, evaluation of mechanical dyssynchrony in the traditional method is based on average of 5 to 10 beats, which is exhausting and time consuming. Single-beat evaluation of a beat with equal subsequent cardiac cycles has been proposed as an accurate method in patients with AF. OBJECTIVES We proposed to evaluate intraventricular mechanical dyssynchrony by measuring time-to-peak systolic velocity between basolateral and basoseptal segments (septum to lateral wall delay) using Tissue Doppler Study (TDI) by two different methods. MATERIALS AND METHODS 31 patient (68 ± 10.3 years) with heart failure (EF < 35%) and AF rhythm, R-R cycle length more than 500 msec were evaluated. We found a target beat in which preceding R-R (R-R1) to pre-preceding R-R (R-R2) ratio was 1(RR1/RR2 = 1) then measured the intraventricular dyssynchrony in that cycle. Intraventricular dyssynchrony was also determined and averaged for 8 consecutive cardiac cycles. The values at RR1/RR2 = 1 were compared with the average of intraventricular dyssynchrony in eight cycles and the relationship between dyssynchrony were evaluated by paired T-test, linear Pearson correlation (r2), linear regression analysis. RESULTS The average of dyssynchrony in eight cycles showed a positive correlation with dyssynchrony in target beat RR1/RR2 = 1. Average of dyssynchrony in target beat was 46.77 msec, and average of 8 cycle was = 47.701, (P value = 0.776, Pearson linear correlation 0.769). CONCLUSIONS Measurement of intraventricular dyssynchromy in basoseptal and basolateral segments in AF and heart failure patients in a single beat with RR1/RR2 = 1 , were very similar to the average value of eight cardiac cycle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical Dyssynchrony is Similar in Different Patterns of Left Bundle-Branch Block

BACKGROUND Left bundle-branch block (LBBB) and the presence of systolic dysfunction are the major indications for cardiac resynchronization therapy (CRT). Mechanical ventricular dyssynchrony on echocardiography can help identify patients responsive to CRT. Left bundle-branch block can have different morphologic patterns. OBJECTIVE To compare the prevalence of mechanical dyssynchrony in differ...

متن کامل

Left Ventricular Dyssynchrony in Patients Showing Diastolic Dysfunction without Overt Symptoms of Heart Failure

BACKGROUND/AIMS Few studies have assessed left ventricular (LV) dyssynchrony in cases of diastolic dysfunction that do not include overt symptoms of heart failure. We hypothesized that systolic or diastolic dyssynchrony involves unique features with respect to the degree of diastolic impairment in isolated diastolic dysfunction. METHODS We examined 105 subjects with no history of overt sympto...

متن کامل

Left Ventricular Systolic Function is Sensitive to Cycle-Length Irregularity in Patients with Atrial Fibrillation and Systolic Dysfunction

Background: Left ventricular (LV) systolic function during atrial fibrillation (AF) is positively correlated with an index of ventricular cycle-length irregularity, the ratio of preceding R-R interval to pre-preceding R-R interval (RRp/RRpp). This study was designed to elucidate the relationship between the RRp/RRpp ratio and LV function, and to identify factors which influence the relationship...

متن کامل

Myocardial contractility is not constant during spontaneous atrial fibrillation in patients.

BACKGROUND The variation in stroke volume and pulse pressure characteristic of atrial fibrillation is usually ascribed to time-dependent ventricular filling, implying a single positive relationship between end-systolic pressure and volume, which defines a single state of myocardial contractility. We tested the hypothesis that contractility also varies. METHODS AND RESULTS We measured the left...

متن کامل

Determination of left ventricular residual function by analysis of post-extrasystolic beat in mitral stenosis.

Residual function of the left ventricle was assessed in 25 patients with mitral stenosis and a normal left ventriculogram. The post-extrasystolic beat (R2) in sinus rhythm (nine patients) and the first beat after an early beat (R2) in atrial fibrillation (16 patients) were analysed angiocardiographically. Five subjects with a normal heart (controls) were also studied. The results are expressed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2013