A treatment planning study of proton arc therapy for para-aortic lymph node tumors: dosimetric evaluation of conventional proton therapy, proton arc therapy, and intensity modulated radiotherapy

نویسندگان

  • Jeong-Eun Rah
  • Gwe-Ya Kim
  • Do Hoon Oh
  • Tae Hyun Kim
  • Jong Won Kim
  • Dae Yong Kim
  • Sung Yong Park
  • Dongho Shin
چکیده

BACKGROUND The purpose of this study is to evaluate the dosimetric benefits of a proton arc technique for treating tumors of the para-aortic lymph nodes (PALN). METHOD In nine patients, a proton arc therapy (PAT) technique was compared with intensity modulated radiation therapy (IMRT) and proton beam therapy (PBT) techniques with respect to the planning target volume (PTV) and organs at risk (OAR). PTV coverage, conformity index (CI), homogeneity index (HI) and OAR doses were compared. Organ-specific radiation induced cancer risks were estimated by applying organ equivalent dose (OED) and normal tissue complication probability (NTCP). RESULTS The PAT techniques showed better PTV coverage than IMRT and PBT plans. The CI obtained with PAT was 1.19 ± 0.02, which was significantly better than that for the IMRT techniques. The HI was lowest for the PAT plan and highest for IMRT. The dose to the OARs was always below the acceptable limits and comparable for all three techniques. OED results calculated based on a plateau dose-response model showed that the risk of secondary cancers in organs was much higher when IMRT or PBT were employed than when PAT was used. NTCPs of PAT to the stomach (0.29 %), small bowel (0.69 %) and liver (0.38 %) were substantially lower than those of IMRT and PBT. CONCLUSION This study demonstrates that there is a potential role for PAT as a commercialized instrument in the future to proton therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A treatment planning comparison of volumetric modulated arc therapy and proton therapy for a sample of breast cancer patients treated with post-mastectomy radiotherapy.

Post-mastectomy radiotherapy (PMRT) has been shown to improve disease-free survival and overall survival for locally advanced breast cancer. However, long term survivors may develop life threatening acute and chronic treatment-related toxicities after radiotherapy, like cardiac toxicity and second cancers. The more advanced techniques like volumetric arc therapy (VMAT), and proton therapy have ...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Proton Therapy for Malignant Pleural Mesothelioma: A Three Case Series Describing the Clinical and Dosimetric Advantages of Proton-Based Therapy

Malignant pleural mesothelioma (MPM) is a malignancy of the pleural cavity that typically presents at an advanced stage. Due to its large, circumferential clinical target volume (CTV) and proximity to major structures, including the heart and contralateral lung, delivering hemithoracic intensity-modulated radiotherapy (IMRT) with photon therapy to achieve loco-regional control following macrosc...

متن کامل

Which technique for radiation is most beneficial for patients with locally advanced cervical cancer? Intensity modulated proton therapy versus intensity modulated photon treatment, helical tomotherapy and volumetric arc therapy for primary radiation – an intraindividual comparison

BACKGROUND To compare highly sophisticated intensity-modulated radiotherapy (IMRT) delivered by either helical tomotherapy (HT), RapidArc (RA), IMRT with protons (IMPT) in patients with locally advanced cervical cancer. METHODS AND MATERIALS Twenty cervical cancer patients were irradiated using either conventional IMRT, VMAT or HT; ten received pelvic (PEL) and ten extended field irradiation ...

متن کامل

Phantom based kV-CBCT dose plan calculations for re-planning decision: comparison with CT-based dose plans

s 17th Annual SASRO Meeting, Davos 2013 Physics Oral P01-22 P01 Phantom based kV-CBCT dose plan calculations for re-planning decision: comparison with CT-based dose plans P01 P02 First experimental results of motion mitigation by continuous line scanning P02 P03 Impact of respiratory-correlated CT reconstruction algorithms in the choice of margin definition for free breathing lung treatment P03...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016