BACKGROUND In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. METHODS Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. RESULTS The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. CONCLUSION In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.
منابع مشابه
International Expert Consensus on Sutureless and Rapid Deployment Valves in Aortic Valve Replacement Using Minimally Invasive Approaches
OBJECTIVE To define the benefit of sutureless and rapid deployment valves in current minimally invasive approaches in isolated aortic valve replacement. METHODS A panel of 28 international experts with expertise in both minimally invasive aortic valve replacement and rapid deployment valves was constituted. After thorough literature review, the experts rated evidence-based recommendations in ...
متن کاملPerceval Sutureless Valve – are Sutureless Valves Here?
With the advent of transcatheter aortic valve implantation (TAVI) techniques, a renewed interest has developed in sutureless aortic valve concepts in the last decade. The main feature of sutureless aortic valve implantation is the speed of insertion, thus making implantation easier for the surgeon. As a result, cross clamp times and myocardial ischemia may be reduced. The combined procedures (C...
متن کاملStent distortion after sutureless aortic valve implantation: a new complication seen with a novel surgical technique.
In recent years, sutureless aortic valves have grown in popularity. As these valves do not need to be anchored with sutures, shorter cardiac ischaemia and extracorporeal circulation times can potentially be achieved. In addition, the absence of a sewing ring in these valves results in a greater effective orifice area for any given size. Postoperative outcome may be improved using sutureless val...
متن کاملIn the era of the valve-in-valve: is transcatheter aortic valve implantation (TAVI) in sutureless valves feasible?
Sutureless aortic valve implantation has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to improve surgical outcomes by facilitating less traumatic minimally invasive approaches and reducing cross-clamp and cardiopulmonary bypass duration. However, the absence of sutures may have detrimental effects after sutureles...
متن کاملAortic valve replacement with sutureless and rapid deployment aortic valve prostheses
Aortic valve stenosis is the most common valve disease in the western world. Over the past few years the number of aortic valve replacement (AVR) interventions has increased with outcomes that have been improved despite increasing age of patients and increasing burden of comorbidities. However, despite such excellent results and its well-established position, conventional AVR has undergone grea...