Elasticity Imaging of the Lung with Fuzzy Control-Based Image Registration Using Multidetector-Row CT

نویسندگان

  • Syoji Kobashi
  • Yosuke Yanagida
  • Katsuya Kondo
  • Yutaka Hata
چکیده

Pulmonary diseases of the lung often cause the change of elasticity. This article proposes a novel elasticity imaging method using multidetector-row CT (MDCT). The new method is based on non-rigid image registration from MDCT images of the inspiratory lung to those of the expiratory lung. The elasticity is calculated by local volume change between respirations. Also, this article introduces a new image registration method based on a fuzzy control system. The fuzzy control deforms the given image according to knowledge on density of lung vessels, shape, and anatomical structure. The proposed elasticity imaging method was evaluated using computer synthetic data and subjects' data. The experimental results showed that the proposed method deformed the given image successfully, and estimated the relative elasticity with a correlation coefficient of 0.86.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Robust Fuzzy Content Based Regularization Technique in Super Resolution Imaging

Super-resolution (SR) aims to overcome the ill-posed conditions of image acquisition. SR facilitates scene recognition from low-resolution image(s). Generally assumes that high and low resolution images share similar intrinsic geometries. Various approaches have tried to aggregate the informative details of multiple low-resolution images into a high-resolution one. In this paper, we present a n...

متن کامل

Lung Lobar Segmentation Using Tubular Tissue Density from Multidetector-row Ct Images

In evaluating thoracic function, it is effective to segment the five lung lobes from multidetector-row computed tomography (MDCT) images. Almost all of the conventional methods are based on extracting the lobar fissures; however, some parts of the fissures may not be observed from MDCT images due to CT artifacts and/or adhesions between the lung lobes. This article proposes an alternative metho...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method

Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007