Isocratic separation of ATP and its degradation products from biological fluids by automated liquid chromatography.
نویسندگان
چکیده
Two groups of metabolites (a) IMP, AMP, ADP, ATP, and cAMP in extracts of fibroblasts and erythrocytes and (b) hypoxanthine, xanthine, adenosine, and inosine in plasma and urine have been separated by ion-pairing reversed-phase chromatography on a microBondapak C18 column, with use of the following reagents: 60 mmol/L KH2PO4, 0.45 mmol/L tetrabutylammonium phosphate, and 1.26 mol/L acetonitrile, pH 3.2 (at 23 degrees C) (group a) and 20 mmol/L KH2PO4, 0.45 mmol/L tetrabutylammonium phosphate, and 0.35 mol/L acetonitrile, pH 2.70 (at 24 degrees C) (group b). Under both sets of conditions, the compounds are completely separated in less than 15 min. The separation is isocratic, so the method is easily adaptable to automation.
منابع مشابه
Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER
An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...
متن کاملDetermination of Synthetic Phenolic Antioxidants in Biological Fluids Based on Air-assisted Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
An air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an a...
متن کاملHigh-performance liquid chromatographic determination of ibuprofen and its major metabolites in biological fluids.
A sensitive and selective high-performance liquid-chromatographic assay for ibuprofen and its major metabolites in biological fluids is described. To ensure good chromatographic separation the drug and metabolites were run on a gradient elution system and detected with a variable wavelength detector set at 220 nm. A second, more rapid, isocratic system is also described for the detection of onl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 34 5 شماره
صفحات -
تاریخ انتشار 1988