Simple, sensitive measurement of carbon monoxide in plasma.

نویسنده

  • A H Chalmers
چکیده

A simple, sensitive method for estimating carbon monoxide in plasma is described. In this method, the carbon monoxide in plasma is trapped with hemoglobin and subsequently estimated by dithionite reduction. The method has an intra- and interassay precision (CV) of 10.7% and 12.8%, respectively, at a concentration of 1.12 mg of carbon monoxide per liter and has a detection limit of 0.1 mg/L. The reference interval for carbon monoxide in plasma from 17 men and eight women ranged from 0.14 to 0.60 mg/L (mean 0.36 mg/L).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

The alveolar carbon monoxide uptake fraction: a simple, alternative measure of carbon monoxide transfer.

The measurement and interpretation of "diffusing capacity" by either single-breath or steady-state methods are complicated by both technical and conceptual difficulties. The CO uptake fraction is less complex but, as originally described, it is unacceptably sensitive to dead-space ventilation. A modification (the "alveolar CO uptake fraction", UA) largely removes this factor. We have measured U...

متن کامل

Toxicological Investigation of Acute Carbon Monoxide Poisoning in ‎Four Occupants of a Fuming Sport Utility Vehicle ‎

Background: This toxicological investigation involves a report on the death of four ‎occupants of a sport utility vehicle on one of the major busy Federal roads of Nigeria ‎where they were held for up to three hours in a traffic jam while the car was steaming.‎ Methods: Autopsy was executed using the standard procedure and toxicological ‎analysis was done using simple spectrophotometric method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 1991