Implementation of Xpert MTB/RIF for routine point-of-care diagnosis of tuberculosis at the primary care level.
نویسندگان
چکیده
Xpert MTB/RIF (Xpert) offers rapid detection of Mycobacterium tuberculosis and rifampicin resistance. However, little is known about routine point-of-care (POC) use in high TB/HIV burden settings. We describe our experiences of launching Xpert as the POC, initial diagnostic for all TB suspects at a primary healthcare clinic in Johannesburg, South Africa. Noted important benefits of POC Xpert were fewer clinic visits, rapid detection of TB and rifampicin resistance, real-time assessment of accompanying household members of new TB cases, and increased staff motivation for TB screening. While Xpert results are available within 2 hours, actual turn-around time was longer for most patients because of sample preparation time and clinic congestion. Consequently, a GX4 instrument did not result in a 16-test capacity during an 8-hour working day, and some patients did not receive same-day results. Loss to follow-up was an unforeseen challenge, overcome by clinic flow changes, marking of clinic files, documenting patients' physical description and locating patients in the clinic by cell phone. Staff with high school education successfully performed the assay after minimal training. Human resource requirements were considerable, with a minimum of 2 staff needed to supervise sputum collection, process sputum, perform assays, and document results for an average of 15 TB suspects daily. POC placement of the instrument transferred logistical responsibilities to the clinic, including quality assurance, maintenance, stock control and cartridge disposal. POC use of Xpert is feasible at the primary healthcare level but must be accompanied by financial, operational and logistical support.
منابع مشابه
The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi
BACKGROUND Current tuberculosis diagnostics lack sensitivity, and are expensive. Highly accurate, rapid and cheaper diagnostic tests are required for point of care use in low resource settings with high HIV prevalence. OBJECTIVE To investigate the sensitivity and specificity, and cost of loop-mediated isothermal amplification (LAMP) assay for tuberculosis diagnosis in adults with chronic coug...
متن کاملCorrection: Impact of Replacing Smear Microscopy with Xpert MTB/RIF for Diagnosing Tuberculosis in Brazil: A Stepped-Wedge Cluster-Randomized Trial
BACKGROUND Abundant evidence on Xpert MTB/RIF accuracy for diagnosing tuberculosis (TB) and rifampicin resistance has been produced, yet there are few data on the population benefit of its programmatic use. We assessed whether the implementation of Xpert MTB/RIF in routine conditions would (1) increase the notification rate of laboratory-confirmed pulmonary TB to the national notification syste...
متن کاملUsing Xpert MTB/RIF
Xpert MTB/RIF is an automated real-time polymerase chain reaction test for simultaneous detection of tuberculosis and rifampicin resistance. Xpert MTB/RIF has demonstrated excellent accuracy in clinical evaluation studies, but has reduced sensitivity for detection of smear-negative tuberculosis. Since sample processing and detection are largely automated, Xpert MTB/RIF is potentially suitable f...
متن کاملTime to Treatment and Patient Outcomes among TB Suspects Screened by a Single Point-of-Care Xpert MTB/RIF at a Primary Care Clinic in Johannesburg, South Africa
INTRODUCTION In December 2010, the World Health Organization recommended a single Xpert MTB/RIF assay as the initial diagnostic in people suspected of HIV-associated or drug resistant tuberculosis. Few data are available on the impact of this recommendation on patient outcomes. We describe the diagnostic follow-up, clinical characteristics and outcomes of a cohort of tuberculosis suspects scree...
متن کاملPopulation-Level Impact of Same-Day Microscopy and Xpert MTB/RIF for Tuberculosis Diagnosis in Africa
OBJECTIVE To compare the population-level impact of two World Health Organization-endorsed strategies for improving the diagnosis of tuberculosis (TB): same-day microscopy and Xpert MTB/RIF (Cepheid, USA). METHODS We created a compartmental transmission model of TB in a representative African community, fit to the regional incidence and mortality of TB and HIV. We compared the population-leve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde
دوره 102 10 شماره
صفحات -
تاریخ انتشار 2012