Efficacy of the New Perilaryngeal Airway (CobraPLA™) Versus the Laryngeal Mask Airway (LMA™) to Improve Oropharyngeal Leak Pressure in Obese and Overweight Patients

نویسندگان

  • Siamak Yaghoobi
  • Seyed Mohamadreza Abootorabi
  • Hamid Kayalha
  • Tom C Van Zundert
  • Amir H Pakpour
چکیده

BACKGROUND This study aimed to evaluate the applicability of Cobra perilaryngeal airway (Cobra PLA™) for obese patients under general anesthesia and also to compare the results with those of classic laryngeal mask airway (LMA™). MATERIALS AND METHODS Seventy-three overweight and obese patients were included in this study. The patients were randomly assigned to LMA™ or Cobra PLA™ groups. Time required for intubation, successful intubation attempt, airway sealing pressure and incidence of complications including blood staining, sore throat and dysphagia were assessed and noted. RESULTS Thirty-six and 37 patients were randomly allocated to LMA™ and Cobra PLA™ groups, respectively. Most patients were males and had Mallampati Class II airway in both groups. The first attempt and overall insertion success for Cobra PLA™ was significantly higher compared to LMA (P<0.05). Airway insertion was more successful (P = 0.027; 94% vs. 77%) with Cobra PLA™. Insertion times were similar with Cobra PLA™ and LMA™ (Cobra PLA™, 29.94±16.35s; LMA™, 27.00±7.88s). The oropharyngeal leak pressure in the Cobra PLA™ group (24.80±0.90 H2O) was significantly higher than that in LMA™ group (19±1 H2O, p<0.001). Sore throat was more frequent in the LMA™ group although it did not reach statistical significance (Fisher's exact test, P = 0.33). Blood staining on airway tube was seen in both groups with a higher incidence in the Cobra PLA™ group (Fisher's Exact test, P = 0.02). Incidence of dysphagia was not different between the two groups. CONCLUSION CobraPLA™ was found to be safe with low complications. It provided better airway sealing with high rate of the first insertion success for use in obese and overweight patients. This study recommends the use of CobraPLA™ as a rescue device in emergency situations for obese and overweight patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

A prospective, randomized comparison of cobra perilaryngeal airway and laryngeal mask airway unique in pediatric patients.

BACKGROUND The Cobra Perilaryngeal Airway (PLA) provides better sealing pressure than the Laryngeal Mask Airway Unique (LMAU) during positive-pressure ventilation in adults. We compared the performance of the CobraPLA and LMAU in infants and children. METHODS Two-hundred pediatric patients were randomly assigned to a CobraPLA or an Laryngeal Mask Airway (LMA). We measured airway sealing at cu...

متن کامل

Brief review: the Cobra Perilaryngeal Airway (CobraPLA and the Streamlined Liner of Pharyngeal Airway (SLIPA) supraglottic airways.

PURPOSE To summarize the published literature related to two, new supraglottic airways (SGAs): the Cobra Perilaryngeal Airway (CobraPLA) and the Streamlined Liner of Pharyngeal Airway (SLIPA). SOURCE We identified original articles, through searches on Medline and PubMed, using the keywords 'Cobra', 'CobraPLA', 'Cobra-PLA', 'PLA', and 'SLIPA'. PRINCIPAL FINDINGS Searches identified 28 publi...

متن کامل

COMPARISON BETWEEN THE EFFICACY OF TRAPEZIUS SQUEEZING TEST AND JAW THRUST MANEUVER FOR PREDICTION OF SUCCESSFUL INSERTION OF LARYNGEAL MASK AIRWAY

Background & Aims: The aim of this study was to compare trapezius squeezing and jaw thrust to evaluate suitable conditions for laryngeal mask airway (LMA) insertion. Materials & Methods: In this clinical trial study, 138 patients with ASA physical status 1 or 2 who were candidates for elective surgery of shin fracture were randomly assigned into one of the groups of trapezius squeeze and raisi...

متن کامل

Hemodynamic responses to insertion of the laryngeal mask airway versus Combitube

Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2015