A novel method to quantify IRDye800CW fluorescent antibody probes ex vivo in tissue distribution studies
نویسندگان
چکیده
UNLABELLED BACKGROUND We describe a new method for biodistribution studies with IRDye800CW fluorescent antibody probes. This method allows the quantification of the IRDye800CW fluorescent tracer in percentage of injected dose per gram of tissue (% ID/g), and it is herein compared to the generally used reference method that makes use of radioactivity. METHODS Cetuximab was conjugated to both the near-infrared fluorophore IRDye800CW and/or the positron emitter 89-zirconium, which was injected in nude mice bearing A431 human tumor xenografts. Positron emission tomography (PET) and optical imaging were performed 24 h post-injection (p.i.). For the biodistribution study, organs and tumors were collected 24 h p.i., and each of these was halved. One half was used for the determination of probe uptake by radioactivity measurement. The other half was homogenized, and the content of the fluorescent probe was determined by extrapolation from a calibration curve made with the injected probe. RESULTS Tumors were clearly visualized with both modalities, and the calculated tumor-to-normal tissue ratios were very similar for optical and PET imaging: 3.31 ± 1.09 and 3.15 ± 0.99, respectively. Although some variations were observed in ex vivo analyses, tumor uptake was within the same range for IRDye800CW and gamma ray quantification: 15.07 ± 3.66% ID/g and 13.92 ± 2.59% ID/g, respectively. CONCLUSIONS The novel method for quantification of the optical tracer IRDye800CW gives similar results as the reference method of gamma ray quantification. This new method is considered very useful in the context of the preclinical development of IRDye800CW fluorescent probes for optical molecular imaging, likely contributing to the selection of lead compounds that are the most promising for clinical translation.
منابع مشابه
Near infrared fluorescence imaging of EGFR expression in vivo using IRDye800CW-nimotuzumab
Nimotuzumab is a humanized anti-epidermal growth factor receptor (EGFR) monoclonal antibody that is approved in many countries for the treatment of EGFR-positive cancers. Near infrared (NIR) fluorescent dye-labeled antibodies represent an attractive class of image-guided surgical probes because of their high specificity, tumor uptake, and low dissociation from tumor cells that express the antig...
متن کاملQuantitative in vivo immunohistochemistry of epidermal growth factor receptor using a receptor concentration imaging approach.
As receptor-targeted therapeutics become increasingly used in clinical oncology, the ability to quantify protein expression and pharmacokinetics in vivo is imperative to ensure successful individualized treatment plans. Current standards for receptor analysis are performed on extracted tissues. These measurements are static and often physiologically irrelevant; therefore, only a partial picture...
متن کاملImmunofluorescence detection with quantum dot bioconjugates for hepatoma in vivo.
The use of highly specific and highly sensitive immunofluorescent probes is a promising approach for biomedical imaging in living tissue. We focus on immunofluorescence with quantum dot bioconjugates for hepatoma detection in vivo. We synthesized specific immunofluorescent probes by linking quantum dots to AFP (alpha-fetoprotein) antibody for specific binding AFP-an important marker for hepatoc...
متن کاملTissue Distribution of 125I-human Nonspecific Polyclonal IgG in Normal and Induced Inflammation Mice
Many different radiolabeled antibodies have been used for radioimmunotherapy and radioimmunoscintigraphy of human diseases in animal experiments. In order to study the in vivo tissue distribution of antibody, we labeled human nonspecific polyclonal IgG with Na125I using chloramine-T method. An animal model was developed by injecting turpentine in the posterior left thigh of Balb/c mice. Tissue ...
متن کاملTissue Distribution of 125I-human Nonspecific Polyclonal IgG in Normal and Induced Inflammation Mice
Many different radiolabeled antibodies have been used for radioimmunotherapy and radioimmunoscintigraphy of human diseases in animal experiments. In order to study the in vivo tissue distribution of antibody, we labeled human nonspecific polyclonal IgG with Na125I using chloramine-T method. An animal model was developed by injecting turpentine in the posterior left thigh of Balb/c mice. Tissue ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2012