Long-term Outcome After Monosegmental L4/5 Stabilization for Degenerative Spondylolisthesis With the Dynesys Device.
نویسندگان
چکیده
STUDY DESIGN Retrospective analysis of prospectively collected clinical data. OBJECTIVE To assess the long-term outcome of patients with monosegmental L4/5 degenerative spondylolisthesis treated with the dynamic Dynesys device. SUMMARY OF BACKGROUND DATA The Dynesys system has been used as a semirigid, lumbar dorsal pedicular stabilization device since 1994. Good short-term results have been reported, but little is known about the long-term outcome after treatment for degenerative spondylolisthesis at the L4/5 level. METHODS A total of 39 consecutive patients with symptomatic degenerative lumbar spondylolisthesis at the L4/5 level were treated with bilateral decompression and Dynesys instrumentation. At a mean follow-up of 7.2 years (range, 5.0-11.2 y), they underwent clinical and radiographic evaluation and quality of life assessment. RESULTS At final follow-up, back pain improved in 89% and leg pain improved in 86% of patients compared with preoperative status. Eighty-three percent of patients reported global subjective improvement. Ninety-two percent would undergo the surgery again. Eight patients (21%) required further surgery because of symptomatic adjacent segment disease (6 cases), late-onset infection (1 case), and screw breakage (1 case). In 9 cases, radiologic progression of spondylolisthesis at the operated segment was found. Seventy-four percent of operated segments showed limited flexion-extension range of <4 degrees. Adjacent segment pathology, although without clinical correlation, was diagnosed at the L5/S1 (17.9%) and L3/4 (28.2%) segments. In 4 cases, asymptomatic screw loosening was observed. CONCLUSIONS Monosegmental Dynesys instrumentation of degenerative spondylolisthesis at L4/5 shows good long-term results. The rate of secondary surgeries is comparable to other dorsal instrumentation devices. Residual range of motion in the stabilized segment is reduced, and the rate of radiologic and symptomatic adjacent segment degeneration is low. Patient satisfaction is high. Dynesys stabilization of symptomatic L4/5 degenerative spondylolisthesis is a possible alternative to other stabilization devices.
منابع مشابه
Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis.
STUDY DESIGN Prospective clinical study. OBJECTIVE To test whether elastic stabilization with the Dynesys system (Zimmer Spine, Minneapolis, MN) provides enough stability to prevent further progression of spondylolisthesis as well as instability after decompression for spinal stenosis with degenerative spondylolisthesis. SUMMARY OF BACKGROUND DATA In spinal stenosis with degenerative spondy...
متن کاملComparison of Dynesys posterior stabilization and posterior lumbar interbody fusion for spinal stenosis L4L5.
The aim of this prospective randomized study was to compare the radiological and clinical outcome after treatment of lumbar spinal stenosis L4L5 with or without spondylolisthesis, with either posterior lumbar interbody fusion (PLIF) (26 patients) or Dynesys posterior stabilization (27 patients). Demographic characteristics were comparable in both groups. Dynesys stabilization resulted in signif...
متن کاملShort-term outcome of transforaminal lumbar interbody fusion for lytic and degenerative spondylolisthesis.
PURPOSE To compare early outcome of transforaminal lumbar interbody fusion (TLIF) for lytic versus degenerative spondylolisthesis. METHODS 14 women and 8 men aged 20 to 60 (mean, 36) years underwent TLIF for lytic (n=15) or degenerative (n=7) spondylolisthesis. Of the 15 patients with lytic spondylolisthesis, 9 involved L4/ L5 and 6 L5/S1. Of the 7 patients with degenerative spondylolisthesis...
متن کاملThe Change of Sagittal Alignment of the Lumbar Spine after Dynesys Stabilization and Proposal of a Refinement
OBJECTIVE Dynesys® is one of the pedicle-based dynamic lumbar stabilization systems and good clinical outcome has been reported. However, the cylindrical spacer between the heads of the screws undergoes deformation during assembly of the system. The pre-strain probably change the angle of instrumented spine with time and oblique-shaped spacer may reduce the pre-strain. We analyzed patients with...
متن کاملUnilateral Pedicle Screw Fixation is Associated with Reduced Cost and Similar Outcomes in Selected Patients Undergoing Minimally Invasive Transforaminal Lumbar Interbody Fusion for L4-5 Degenerative Spondylolisthesis
STUDY DESIGN Retrospective study of 24 patients who underwent either a bilateral or unilateral TLIF procedure for the treatment of degenerative spondylolisthesis. OBJECTIVE To analyze differences in cost and outcome between patients undergoing minimally invasive transforaminal lumbar interbody fusion (mi-TLIF) with unilateral or bilateral pedicle screw fixation for L4-5 degenerative spondylol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical spine surgery
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2016