Physiologic response to changing positive end-expiratory pressure during neurally adjusted ventilatory assist in sedated, critically ill adults.

نویسندگان

  • Christina Passath
  • Jukka Takala
  • Daniel Tuchscherer
  • Stephan M Jakob
  • Christer Sinderby
  • Lukas Brander
چکیده

BACKGROUND Neurally adjusted ventilatory assist (NAVA) delivers airway pressure (Paw) in proportion to neural inspiratory drive as reflected by electrical activity of the diaphragm (EAdi). Changing positive end-expiratory pressure (PEEP) impacts respiratory muscle load and function and, hence, EAdi. We aimed to evaluate how PEEP affects the breathing pattern and neuroventilatory efficiency during NAVA. METHODS In 20 adult patients, adequate assist (NAVAal) was first identified based on Paw and tidal volume (Vt) responses to systematic increases in NAVA level while using preset PEEP (PEEPbl). Thereafter, using NAVAal, PEEP was increased to 20 cm water (H(2)O) (PEEPhigh) and then lowered stepwise to 1 cm H(2)O (PEEP1). EAdi, Paw, and Vt were recorded. RESULTS Median NAVAal was 2.7 (interquartile range, 2.3-3.5) cm H(2)O/muV and was similar to NAVAal identified post hoc by 17 independent physicians (2.5 [2.0-3.4] cm H(2)O/muV; P = NS). Reducing PEEPhigh to PEEP1 increased inspiratory EAdi by 34% (2-67; P = .046) and was associated with an increase in mean Paw above PEEP from 8.5 (6.7-11.4) cm H(2)O to 12.2 (8.8-16.7) cm H(2)O (P = .008), whereas Vt and respiratory rate remained unchanged. The response pattern in Vt/EAdi, indicating changes in neuroventilatory efficiency, differed among patients. Tidal breathing occurred at the lowest EAdi cost in seven patients with PEEP1 or half PEEPbl, in six patients with PEEPbl, and in seven patients with PEEPhigh. CONCLUSIONS During NAVAal, increasing PEEP reduces respiratory drive. Patients adapt their neuroventilatory efficiency such that the individual ventilatory pattern is preserved over a wide range of PEEP levels. Monitoring Vt/EAdi during PEEP changes allows identification of a PEEP level at which tidal breathing occurs at minimal EAdi cost. TRIAL REGISTRATION clinicaltrials.gov; Identifier: NCT00529347.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

0438. Effects of positive end-expiratory pressure (PEEP) on the pattern of breathing during neurally adjusted ventilatory assist. A pilot study in a mild ards porcine model

Introduction Spontaneous breathing during mechanical ventilation is still controversial. It is well known that incongruous patterns of mechanical ventilation can trigger or exacerbate lung injury. NAVA is a mode of mechanical ventilation that delivers ventilatory assist in proportion to the Electrical activity of the Diaphragm (EDi), which mirrors the performance of the whole respiratory system...

متن کامل

Feasibility of neurally adjusted positive end-expiratory pressure in rabbits with early experimental lung injury

BACKGROUND During conventional Neurally Adjusted Ventilatory Assist (NAVA), the electrical activity of the diaphragm (EAdi) is used for triggering and cycling-off inspiratory assist, with a fixed PEEP (so called "Triggered Neurally Adjusted Ventilatory Assist" or "tNAVA"). However, significant post-inspiratory activity of the diaphragm can occur, believed to play a role in maintaining end-expir...

متن کامل

Patient-ventilator asynchrony during noninvasive pressure support ventilation and neurally adjusted ventilatory assist in infants and children*.

OBJECTIVES To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING The study was performed in a PICU. PATIENTS From 4 weeks to 5 years. INTERVENTI...

متن کامل

Initiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran

Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...

متن کامل

Clinical assessment of auto-positive end-expiratory pressure by diaphragmatic electrical activity during pressure support and neurally adjusted ventilatory assist.

BACKGROUND Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 138 3  شماره 

صفحات  -

تاریخ انتشار 2010