Noncoplanar verification: a feasibility study using Philips' Pinnacle3 treatment planning system

نویسندگان

  • Indra Yohannes
  • Heru Prasetio
  • Christoph Bert
چکیده

Noncoplanar fields are normally used to improve the dose conformity of the target while sparing organs at risk. One of the methods to verify the dose distribution from the noncoplanar fields is by comparing their planar dose distributions from the treatment planning system (TPS) and the measured ones; for example, using film or electronic portal imaging devices (EPID). The planar dose distributions of the measurement tools, that are normally perpendicular to the central axis of the beam, can be calculated by creating special structures to mimic them in the TPS. With TPS commercially available today, however, it is not easy to create these special structures, especially in the noncoplanar configuration. For this work, we have written in-house scripts in the Pinnacle(3) TPS that can create the structures and define them as virtual planes. These virtual planes can be generated for any arbitrary gantry and couch angles, as well as source to planar distance, so that the planar dose maps at these planes can be computed. Two independent quality assurance (QA) tools were used to validate the planar dose distributions computed using the scripts for three open fields and one IMRT field at several different couch angles. The absolute planar dose patterns measured by the QA tools for all fields at all couch angles were found to be in good agreement, more than 95% (gamma criteria 3% delta dose and 3 mm distance to agreement), with the calculated ones by TPS. The results of this feasibility study can be valuable either for pretreatment dose verification or for in vivo dosimetry that directly implements the planar dose distributions from the TPS, particularly for the noncoplanar fields.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo prostate IMRT dosimetry with MOSFET detectors using brass buildup caps

The feasibility of using dual bias metal oxide semiconductor field effect transistors (MOSFET) detectors with the new hemispherical brass build up cap for in vivo dose measurements in Prostate IMRT treatments was investigated and achieved. A general formalism with various correction factors taken into account to predict Dmax entrance skin dose for the IMRT fields with MOSFETS was developed and ...

متن کامل

Volumetric modulated arc therapy for total body irradiation: A feasibility study using Pinnacle3 treatment planning system and Elekta Agility™ linac

A study was undertaken to explore the use of volumetric modulated arc therapy (VMAT) for total body irradiation (TBI). Five patient plans were created in Pinnacle3 using nine 6 MV photon dynamic arcs. A dose of 12 Gy in six fractions was prescribed. The planning target volume (PTV) was split into four subsections for the head, chest, abdomen, and pelvis. The head and chest beams were optimized ...

متن کامل

Beam modeling and VMAT performance with the Agility 160‐leaf multileaf collimator

The Agility multileaf collimator (Elekta AB, Stockholm, Sweden) has 160 leaves of projected width 0.5 cm at the isocenter, with maximum leaf speed 3.5 cms-1. These characteristics promise to facilitate fast and accurate delivery of radiotherapy, particularly volumetric-modulated arc therapy (VMAT). The aim of this study is therefore to create a beam model for the Pinnacle3 treatment planning sy...

متن کامل

Comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film with a commercial radiation treatment planning system for breast IMRT: a feasibility study

This work presents a comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film measurements with a commercial treatment planning system to determine the feasibility of PRESAGE® for 3D dosimetry in breast IMRT. An anthropomorphic PRESAGE® phantom was created in the shape of a breast phantom. A five-field IMRT plan was generated with a commercially available treatment planning sys...

متن کامل

Quality assurance: Fundamental reproducibility tests for 3D treatment‐planning systems

The use of image-based 3D treatment planning has significantly increased the complexity of commercially available treatment-planning systems (TPSs). Medical physicists have traditionally focused their efforts on understanding the calculation algorithm; this is no longer possible. A quality assurance (QA) program for our 3D treatment-planning system (ADAC Pinnacle3) is presented. The program is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015