SiNG-PCRseq: Accurate inter-sequence quantification achieved by spiking-in a neighbor genome for competitive PCR amplicon sequencing

نویسندگان

  • Soo A. Oh
  • Inchul Yang
  • Yoonsoo Hahn
  • Yong-Kook Kang
  • Sun-Ku Chung
  • Sangkyun Jeong
چکیده

Despite the recent technological advances in DNA quantitation by sequencing, accurate delineation of the quantitative relationship among different DNA sequences is yet to be elaborated due to difficulties in correcting the sequence-specific quantitation biases. We here developed a novel DNA quantitation method via spiking-in a neighbor genome for competitive PCR amplicon sequencing (SiNG-PCRseq). This method utilizes genome-wide chemically equivalent but easily discriminable homologous sequences with a known copy arrangement in the neighbor genome. By comparing the amounts of selected human DNA sequences simultaneously to those of matched sequences in the orangutan genome, we could accurately draw the quantitative relationships for those sequences in the human genome (root-mean-square deviations <0.05). Technical replications of cDNA quantitation performed using different reagents at different time points also resulted in excellent correlations (R(2) > 0.95). The cDNA quantitation using SiNG-PCRseq was highly concordant with the RNA-seq-derived version in inter-sample comparisons (R(2) = 0.88), but relatively discordant in inter-sequence quantitation (R(2) < 0.44), indicating considerable level of sequence-dependent quantitative biases in RNA-seq. Considering the measurement structure explicitly relating the amount of different sequences within a sample, SiNG-PCRseq will facilitate sharing and comparing the quantitation data generated under different spatio-temporal settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Targeted RNA-Sequencing with Competitive Multiplex-PCR Amplicon Libraries

Whole transcriptome RNA-sequencing is a powerful tool, but is costly and yields complex data sets that limit its utility in molecular diagnostic testing. A targeted quantitative RNA-sequencing method that is reproducible and reduces the number of sequencing reads required to measure transcripts over the full range of expression would be better suited to diagnostic testing. Toward this goal, we ...

متن کامل

Development of a Sensitive Quantitative Competitive PCR Assay for Detection of Human Cytomegalovirus DNA

Accurate and rapid diagnosis of human cytomegalovirus (HCMV) disease in immunocompromised patients has remained as a challenge. Quantitative competitive PCR (QC-PCR) methods for detection of HCMV in these individuals have improved the positive and negative predictive values of PCR for diagnosis of HCMV disease. In this study we used QC-PCR assay, using a co-amplified DNA standard, to quantitate...

متن کامل

Multiplex PCR Targeted Amplicon Sequencing (MTA-Seq): Simple, Flexible, and Versatile SNP Genotyping by Highly Multiplexed PCR Amplicon Sequencing

Next-generation sequencing (NGS) technologies have enabled genome re-sequencing for exploring genome-wide polymorphisms among individuals, as well as targeted re-sequencing for the rapid and simultaneous detection of polymorphisms in genes associated with various biological functions. Therefore, a simple and robust method for targeted re-sequencing should facilitate genotyping in a wide range o...

متن کامل

Detection and Characterization of Weissellicin 110, a Bacteriocin Produced by Weissella cibaria

Background: Weissellicin 110 is the only bacteriocin reported in Weissella cibaria up to now. This bacteriocin represents several unique features. This is the first report on the gene sequence that encodes for the bacteriocin. Objectives: Providing a rapid detection method to isolate the weissellicin 110 encoding gene and determination of the bacteriocin distribution were the objectives. Materi...

متن کامل

Integrating nested PCR with high-throughput sequencing to characterize mutations of HBV genome in low viral load samples

Due to the low viral load of hepatitis B virus (HBV) in plasma samples, conventional techniques have limitations to the detection of antiviral resistance mutations. To solve the problem, we developed a fast, highly sensitive, and accurate method to sequence the HBV whole-genome sequencing in plasma samples which had various viral loads from very low to high.Twenty-one plasma samples were collec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015