Imaging linear and circular polarization features in leaves with complete Mueller matrix polarimetry.

نویسندگان

  • C H Lucas Patty
  • David A Luo
  • Frans Snik
  • Freek Ariese
  • Wybren Jan Buma
  • Inge Loes Ten Kate
  • Rob J M van Spanning
  • William B Sparks
  • Thomas A Germer
  • Győző Garab
  • Michael W Kudenov
چکیده

Spectropolarimetry of intact plant leaves allows to probe the molecular architecture of vegetation photosynthesis in a non-invasive and non-destructive way and, as such, can offer a wealth of physiological information. In addition to the molecular signals due to the photosynthetic machinery, the cell structure and its arrangement within a leaf can create and modify polarization signals. Using Mueller matrix polarimetry with rotating retarder modulation, we have visualized spatial variations in polarization in transmission around the chlorophyll a absorbance band from 650 nm to 710 nm. We show linear and circular polarization measurements of maple leaves and cultivated maize leaves and discuss the corresponding Mueller matrices and the Mueller matrix decompositions, which show distinct features in diattenuation, polarizance, retardance and depolarization. Importantly, while normal leaf tissue shows a typical split signal with both a negative and a positive peak in the induced fractional circular polarization and circular dichroism, the signals close to the veins only display a negative band. The results are similar to the negative band as reported earlier for single macrodomains. We discuss the possible role of the chloroplast orientation around the veins as a cause of this phenomenon. Systematic artefacts are ruled out as three independent measurements by different instruments gave similar results. These results provide better insight into circular polarization measurements on whole leaves and options for vegetation remote sensing using circular polarization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Roles of linear and circular polarization properties and effect of wavelength choice on differentiation between ex vivo normal and cancerous gastric samples.

Multispectral Mueller matrix imaging was performed over a spectral range from 470 to 632 nm on 4-μm unstained gastric tissue sections. A complete set of polarization parameters was derived. The combination of linear depolarization and linear retardance yields the highest accuracy in sample classification. When the depolarization of linearly polarized light due to scattering is independent of th...

متن کامل

Double-pass axially resolved confocal Mueller matrix imaging polarimetry.

We present experimental depth-resolved complete polarization-sensitive measurements of a stack of linear retarders and glass plates by using what is to the best of our knowledge the first combination of a confocal imaging system with a complete Mueller matrix polarimeter. The axially resolved Mueller matrices were compared with a forward simulation, with good agreement.

متن کامل

Annals of Biomedical Research and Education

The Mueller matrix polarimetry is a useful technique for characterization and imaging of biological materials and turbid medium. The recoded transmitted Mueller matrix elements are highly intensity and wavelength dependent. We derived the sixteen Mueller matrix images out of forty-nine polarization configurations for characterization of the polystyrene sphere of 0.2 to 20 μm illuminated with po...

متن کامل

Polarized Mueller Matrix Analytical Model for Glucose Measurement in Vitro

In this study we present a noninvasive and nonradioactive glucose in vitro measurement technique using the Mueller polarization analytical model. The glucose solution and aqueous humor phantoms are illuminated with a He-Ne (632.8 nm) laser. This in vitro study provides a base and reference data for in vivo eye glucose monitoring. The 16 Mueller polarization matrix element images give informatio...

متن کامل

Polar decomposition of 3 x 3 Mueller matrix: a tool for quantitative tissue polarimetry.

The polarization properties of any medium are completely described by the sixteen element Mueller matrix that relates the polarization parameters of the light incident on the medium to that emerging from it. Measurement of all the elements of the matrix requires a minimum of sixteen measurements involving both linear and circularly polarized light. However, for many diagnostic applications, it ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biochimica et biophysica acta

دوره 1862 6  شماره 

صفحات  -

تاریخ انتشار 2018