A Cadaver Reliability Study

نویسندگان

  • J. M. F. Spencer
  • R. E. Day
  • K. E. Sloan
  • R. J. Beaver
چکیده

J Bone Joint Surg [Br] 2006;88-B:972-5. Received 28 November 2005; Accepted after revision 16 March 2006 Our aim was to assess the intraand inter-observer reliability in the establishment of the anterior pelvic plane used in imageless computer-assisted navigation. From this we determined the subsequent effects on version and inclination of the acetabular component. A cadaver model was developed with a specifically-designed rod which held the component tracker at a fixed orientation to the pelvis, leaving the anterior pelvic plane as the only variable. Eight surgeons determined the anterior pelvic plane by palpating and registering the bony landmarks as reference points. The exact anterior pelvic plane was then established by using anatomically-placed bone screws as reference points. The difference between the surgeons was found to be highly significant (p < 0.001). The variation was significantly larger for anteversion ( SD 9.6 ̊) than for inclination ( SD 6.3 ̊). The present method for registering pelvic landmarks shows significant inaccuracy, which highlights the need for improved methods of registration before this technique is considered to be safe.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cadaver dogs--a study on detection of contaminated carpet squares.

INTRODUCTION Cadaver dogs are known as valuable forensic tools in crime scene investigations. Scientific research attempting to verify their value is largely lacking, specifically for scents associated with the early postmortem interval. The aim of our investigation was the comparative evaluation of the reliability, accuracy, and specificity of three cadaver dogs belonging to the Hamburg State ...

متن کامل

Reliability of limb alignment measurement for high tibial osteotomy with a navigation system

OBJECTIVE High tibial osteotomy (HTO) is one treatment option for young and active patients with unicompartmental osteoarthritis. The success of this procedure substantially depends on the degree of correction of the mechanical axis. Computer-assisted navigation systems are believed to improve the precision of axis correction through intraoperative real-time monitoring. This study investigates ...

متن کامل

Dynamic contour tonometry: a comparative study on human cadaver eyes.

OBJECTIVE To compare intraocular pressure measurements obtained by recently introduced dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT), pneumatonometry (PTG), and intracameral manometry in human cadaver eyes. METHODS Sixteen freshly enucleated human cadaver eyes were deepithelialized and dehydrated with dextran. A tube was placed in the anterior chamber and connected to ...

متن کامل

Reliability of superficial male pelvic floor structural measurements using linear-array transperineal sonography.

This study evaluated reliability of measures for superficial structures of the male pelvic floor (PF) obtained via transperineal sonography. Two embalmed cadavers were dissected to identify positioning of muscles on and around the bulb of the penis and to confirm the PF protocol. Cross-sectional area (CSA) and linear thickness of the bulb of the penis, urethra, bulbospongiosus (BS) muscles, and...

متن کامل

A novel technique for measurement of dentogingival tissue by cone beam computed tomography.

OBJECTIVES To develop a novel technique to visualize dentogingival profiles by using cone beam computed tomography (CBCT) and to evaluate the accuracy of mucogingival tissue thickness measurements with CBCT, as compared with direct measurements in vitro. METHODS A silicone matrix loaded with radiopaque impression material was prepared before performing CBCT on a patient. Two dry cadaver mandi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006