Long-term clinical outcomes after deployment of femoral vascular closure devices in coronary angiography and percutaneous coronary intervention: an observational single-centre registry follow-up

نویسندگان

  • Stephen Wai-Luen Lee
  • Chor-Cheung Tam
  • Ka-Lam Wong
  • Shun-Ling Kong
  • See-Yue Yung
  • Yiu-Tung Wong
  • Suk-Yee Chiu
  • Cheung-Chi Lam
  • Ki-Wan Chan
  • Hon-Wah Chan
چکیده

BACKGROUND We evaluated the long term clinical outcomes of femoral vascular closure devices following its deployment in coronary angiography and percutaneous coronary intervention (PCI) procedures. METHODS From June 2000 to September 2004, 265 patients who received femoral vascular closure devices after coronary angiography and PCIs were enrolled into the study. Patients' medical records were reviewed and vascular complications within 1 year of follow-up period were recorded. Rutherford's categories of claudication were used to quantify different degrees of claudication and leg ischaemia. Duplex ultrasonography of both femoral arteries (using the nonaccessed site as control) was performed at 1 year after deployment of vascular closure devices. Vessel diameter and flow velocities for both common femoral arteries were obtained. RESULTS There was no occurrence of late vascular complications like arteriovenous fistula, pseudoaneurysm, surgical repair of access site complications, late groin bleeding and infection. By Rutherford categories of claudication, 99.2% of patients had grade 0 claudication while the remaining 0.8% was in grade 1. By arterial Duplex ultrasonography, the peak systolic velocity of the accessed femoral artery (predominantly right side) was nonsignificantly higher, 94.9 + or - 26.0 cm/s when compared to 91.5 + or - 24.8 cm/s in the control site (P = 0.12). As for vessel diameter, no significant difference was found in the mean end-diastolic vessel diameter 8.8 + or - 1.3 mm (puncture site) versus 8.7 + or - 4.4 mm (control site) (P = 0.72). CONCLUSION We found that the use of femoral closure devices was safe and it was not associated with any adverse long term vascular complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Rationale of the Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) Study

BACKGROUND Bleeding events after percutaneous coronary interventions (PCI) are associated with patients' age, gender, and the presence of chronic kidney disease, antithrombotic treatment, as well as arterial access site. Patients being treated by PCI using radial access site are associated with an improved prognosis. However, the safety of femoral closure devices has never been compared to radi...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

The Relation of Serum Bilirubin Level with the Severity and Complexity of Coronary Artery Disease and Long-term Outcomes in the Patients Undergoing Primary Percutaneous Coronary Intervention

Background and Aims: Bilirubin has been considered an antioxidant that protects against atherosclerosis. The aim of this study was to evaluate the relationship of serum bilirubin level with the severity and complexity of coronary artery disease (CAD) and long-term outcome in the patients undergoing primary percutaneous coronary intervention (PCI). Materials and Methods: This prospective coho...

متن کامل

Clinical and Subclinical Femoral Vascular Complications after Deployment of two Different Vascular Closure Devices or Manual Compression in the Setting of Coronary Intervention.

BACKGROUND In the past two decades vascular closure devices (VCD) have been increasingly utilized as an alternative to manual compression after percutaneous femoral artery access. However, there is a lack of data confirming a significant reduction of vascular complication in a routine interventional setting. Systematic assessment of puncture sites with ultrasound was hardly performed. METHODS...

متن کامل

A propensity analysis of the risk of vascular complications after cardiac catheterization procedures with the use of vascular closure devices.

BACKGROUND Complications of vascular access are one of the most common adverse events after coronary angiography and percutaneous coronary intervention (PCI) and are reported to occur in 1% to 9% of cases. There are conflicting reports of the association of vascular complications with the use of vascular closure devices (VCDs). The purpose of this study was to assess femoral arterial access-rel...

متن کامل