Effects of multilevel posterior ligament dissection after spinal instrumentation on adjacent segment biomechanics as a potential risk factor for proximal junctional kyphosis: a biomechanical study
نویسندگان
چکیده
BACKGROUND Spinous processes and posterior ligaments, such as inter- and supraspinous ligaments are often sacrificed either deliberately to harvest osseous material for final spondylodesis e.g. in deformity corrective surgery or accidentally after posterior spinal instrumentation. This biomechanical study evaluates the potential destabilizing effect of a progressive dissection of the posterior ligaments (PL) after instrumented spinal fusion as a potential risk factor for proximal junctional kyphosis (PJK). METHODS Twelve calf lumbar spines were instrumented from L3 to L6 (L3 = upper instrumented vertebra, UIV) and randomly assigned to one of the two study groups (dissection vs. control group). The specimens in the dissection group underwent progressive PL dissection, followed by cyclic flexion motion (250 cycles, moment: + 2.5 to + 20.0 Nm) to simulate physical activity and range of motion (ROM) testing of each segment with pure moments of ±15.0 Nm after each dissection step. The segmental ROM in flexion and extension was measured. The control group underwent the same loading and ROM testing protocol, but without PL dissection. RESULTS In the treatment group, the normalized mean ROM at L2-L3 (direct adjacent segment of interest, UIV/UIV + 1, PJK-level) increased to 104.7%, 107.3%, and 119.4% after dissection of the PL L4-L6, L3-L6, and L2-L6, respectively. In the control group the mean ROM increased only to 103.2%, 106.7%, and 108.7%. The ROM difference at L2-L3 with regard to the last dissection of the PL was statistically significant (P = 0.017) and a PL dissection in the instrumented segments showed a positive trend towards an increased ROM at UIV/UIV + 1. CONCLUSIONS A dissection of the PL at UIV/UIV + 1 leads to a significant increase in ROM at this level which can be considered to be a risk factor for PJK and should be definitely avoided during surgery. However, a dissection of the posterior ligaments within the instrumented segments while preserving the ligaments at UIV/UIV + 1 leads to a slight but not significant increase in ROM in the adjacent cranial segment UIV/UIV + 1 in the used experimental setup. Using this experimental setup we could not confirm our initial hypothesis that the posterior ligaments within a long posterior instrumentation should be preserved.
منابع مشابه
Proximal junctional kyphosis in adolescent idiopathic scoliosis following segmental posterior spinal instrumentation and fusion minimum 2 years follow-up
Abstract Background: To evaluate proximal junctional segment changes in Adolescent Idiopathic Scoliosis(AIS) the posterior spinal fusion and also instrumentation also and finding of probable risk factors, were all considered in this study. Methods: We retrospectively reviewed radiographs of 121 consecutive patients who underwent posterior spinal fusion for AIS from T3 or below, with...
متن کاملDiagnosis and Classification of Proximal Junctional Kyphosis and Proximal Junctional Failure
Pedicle screw instrumentation constructs have become a cornerstone in the treatment of adult spinal deformity and instability. They are known to provide greater rigidity and enhanced ability to correct and maintain spinal alignment. Biomechanical data, however, demonstrate that increased construct stiffness is associated with increased loading within adjacent segments [1– 9]. Increasingly stiff...
متن کاملSemitendinosus Graft for Interspinous Ligament Reinforcement in Adult Spinal Deformity.
Proximal junctional kyphosis is an increasingly recognized complication following long-segment posterior spinal fusion for adult spinal deformity. The authors describe a novel technique for interspinous ligament reinforcement at the proximal adjacent levels using a cadaveric semitendinosus tendon graft secured with an Ethibond No. 2 double filament (Ethicon, Somerville, New Jersey) via the Krac...
متن کاملThe quantitative assessment of contribution of risk factors to overstress at adjacent segments after lumbar fusion: removal of posterior ligaments, pedicle screws
Adjacent segment deterioration (ASD) is a serious sequela of spinal fusion surgery that has recently become much more widespread due to an increasing number of spinal fusions performed [1]. Moreover, previous studies [2] of potential risk factors for ASD have found that instrumentation, posterior lumbar interbody fusion, injury to the facet joint of the adjacent segment, fusion length, age, and...
متن کاملBiomechanical Analysis of the Proximal Adjacent Segment after Multilevel Instrumentation of the Thoracic Spine: Do Hooks Ease the Transition?
Study Design Biomechanical cadaveric study. Objective Clinical studies indicate that using less-rigid fixation techniques in place of the standard all-pedicle screw construct when correcting for scoliosis may reduce the incidence of proximal junctional kyphosis and improve patient outcomes. The purpose of this study is to investigate whether there is a biomechanical advantage to using supralami...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -