چکیده

INTRODUCTION Central venous cannulation is crucial in the management of the critical care patient. This study was designed to evaluate whether real-time ultrasound-guided cannulation of the internal jugular vein is superior to the standard landmark method. METHODS In this randomised study, 450 critical care patients who underwent real-time ultrasound-guided cannulation of the internal jugular vein were prospectively compared with 450 critical care patients in whom the landmark technique was used. Randomisation was performed by means of a computer-generated random-numbers table, and patients were stratified with regard to age, gender, and body mass index. RESULTS There were no significant differences in gender, age, body mass index, or side of cannulation (left or right) or in the presence of risk factors for difficult venous cannulation such as prior catheterisation, limited sites for access attempts, previous difficulties during catheterisation, previous mechanical complication, known vascular abnormality, untreated coagulopathy, skeletal deformity, and cannulation during cardiac arrest between the two groups of patients. Furthermore, the physicians who performed the procedures had comparable experience in the placement of central venous catheters (p = non-significant). Cannulation of the internal jugular vein was achieved in all patients by using ultrasound and in 425 of the patients (94.4%) by using the landmark technique (p < 0.001). Average access time (skin to vein) and number of attempts were significantly reduced in the ultrasound group of patients compared with the landmark group (p < 0.001). In the landmark group, puncture of the carotid artery occurred in 10.6% of patients, haematoma in 8.4%, haemothorax in 1.7%, pneumothorax in 2.4%, and central venous catheter-associated blood stream infection in 16%, which were all significantly increased compared with the ultrasound group (p < 0.001). CONCLUSION The present data suggest that ultrasound-guided catheterisation of the internal jugular vein in critical care patients is superior to the landmark technique and therefore should be the method of choice in these patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique.

BACKGROUND Central venous access is an essential part of patient management in many clinical settings and is usually achieved with a blinded, external landmark-guided technique. The purpose of this study is to evaluate whether an ultrasound technique can improve on the traditional method. METHODS AND RESULTS We prospectively evaluated an ultrasound-guided method in 302 patients undergoing int...

متن کامل

Internal Jugular Vein Cannulation: An Ultrasound-Guided Technique Versus a Landmark-Guided Technique

OBJECTIVES To compare the landmark-guided technique versus the ultrasound-guided technique for internal jugular vein cannulation in spontaneously breathing patients. METHODS A total of 380 patients who required internal jugular vein cannulation were randomly assigned to receive internal jugular vein cannulation using either the landmark- or ultrasound-guided technique in Bursa, Uludag Univers...

متن کامل

Ultrasound versus the landmark technique: a prospective randomized comparative study of internal jugular vein cannulation in an intensive care unit.

OBJECTIVE The aim of this study is to find out if an ultrasound technique has advantages over the conventional landmark technique. METHODS This is a prospective randomized comparative study on 120 patients requiring central venous cannulation of the right internal jugular vein. The study comprised of two groups: ultrasound and landmark groups, each consisting of 60 patients. The outcome measu...

متن کامل

Tracheal intubation in the critically ill: just say no to drugs.

vein location: impact of central venous access. Crit Care Med 1991; 19: 1516–9 3 Sulek CA, Gravenstein N, Blackshear RH, Weiss L. Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture. Anesth Analg 1996; 82: 125–8 4 Reuber M, Dunkley LA, Turton EPL, Bell MDD, Bamford JM. Stroke after internal jugular venous cannulation. Acta Neurol Scand 2002; 105: 235–9...

متن کامل

Ultrasonic locating devices for central venous cannulation: meta-analysis.

OBJECTIVES To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. DATA SOURCES 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. DESIGN Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVEN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical Care

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2006