The Reiter protein complement-fixation test using the Auto-Analyzer.

نویسندگان

  • V W Pugh
  • R W Gaze
چکیده

A method for the Reiter protein complement-fixation test using the Techncon AutoAnalyzer is described. Two hundred and fifty sera were tested, when six false-positive and nine false-negative results were obtained when compared with results obtained by the manual method. Deep freezing the sera before testing on the AutoAnalyzer increased the sensitivity so that in a further 250 sera tested no false-negative and two false-positive results were obtained when compared with the results obtained at the Venereal Diseases Reference Laboratory, London.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Growth enhancement of the Reiter treponeme by fatty acids.

Interest in the Reiter strain of Treponema pallidum, a nonpathogenic, cultivatable, anaerobic spirochete, has been stimulated by the demonstration that the organism possesses four antigens; one, a thermolabile protein, being group specific for treponemes (D'Alessandro et al., 1949). This antigen has recently been employed in a Reiter protein complement fixation test for syphilis (Cannefax and G...

متن کامل

Reiter protein antigen. I. Relationship of some physical and chemical characteristics to serological activity.

The Italian workers D'Alessandro, Oddo, Comes, and Dardanoni (1949) and D'Alessandro and Dardanoni (1953) described the isolation of four serologically active components of Reiter's treponeme. These contributions represent milestones in the sero-diagnosis of syphilis since they were the initial systematic investigations into the serological components of treponemes. One of the components was co...

متن کامل

Evaluation of automated large-scale screening tests for syphilis.

Two methods of performing serological screening tests for syphilis are compared. One consisted of the Venereal Diseases Reference Laboratory (VDRL) slide test, the cardiolipin Wassermann reaction (CWR), and the Reiter protein complement fixation test (RPCFT) performed manually; the other was a fully automated system using two Technicon AutoAnalyzers (AAII), one for the automated reagin test (AR...

متن کامل

Reiter haemagglutination test: a screening test for syphilis.

Using an ultrasonicate of the Reiter treponeme as antigen the Reiter haemagglutination test (RHA) was evaluated as a serological test for syphilis. Comparison of the results of the cardiolipin Wassermann reaction, Reiter protein complement-fixation test, the fluorescent treponemal antibody-absorbed (FTA-ABS) test, the Treponema pallidum haemagglutination test (TPHA) (at dilutions of 1/16 and 1/...

متن کامل

Specificity and Sensitivity of the Reiter Protein Complement - Fixation ( Rpcf ) Test *

The reliability of the sero-diagnosis of syphilis depends on the specificity and the sensitivity of the tests used. The specificity of a test is determined by the nature of the antigen; the sensitivity depends mainly on the technique by which the test is performed. The most specific though not the most sensitive test at the moment is, without doubt, the T. pallidum immobilization (TPI) test of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 1966