A feedback-controlled treadmill (treadmill-on-demand) and the spontaneous speed of walking and running in humans.
نویسندگان
چکیده
A novel apparatus, composed by a controllable treadmill, a computer, and an ultrasonic range finder, is here proposed to help investigation of many aspects of spontaneous locomotion. The acceleration or deceleration of the subject, detected by the sensor and processed by the computer, is used to accelerate or decelerate the treadmill in real time. The system has been used to assess, in eight subjects, the self-selected speed of walking and running, the maximum "reasonable" speed of walking, and the minimum reasonable speed of running at different gradients (from level up to +25%). This evidenced the speed range at which humans neither walk nor run, from 7.2 +/- 0.6 to 8.4 +/- 1.1 km/h for level locomotion, slightly narrowing at steeper slopes. These data confirm previous results, obtained indirectly from stride frequency recordings. The self-selected speed of walking decreases with increasing gradient (from 5.0 +/- 0.8 km/h at 0% to 3.0 +/- 0.9 km/h at +25%) and seems to be approximately 30% higher than the speed that minimizes the metabolic energy cost of walking, obtained from the literature, at all the investigated gradients. The advantages, limitations, and potential applications of the newly proposed methodology in physiology, biomechanics, and pathology of locomotion are discussed in this paper.
منابع مشابه
COMPARING EFFICIENCY OF EXERCISE ON THE TREADMILL AND GROUND ON THE GROUND REACTION FORCES DURING WALKING IN PEOPLE WITH GENU VARUM
Background & Aim: Genu varum is one of the most common abnormalities of the knee joint in which the inner condyles of the femur move away from each other. The aim of the present study was to compare efficiency of exercise on the treadmill and ground on the ground reaction forces during walking in people with genu varum. Material & Methods: The present study was a quasi-experimental and laborat...
متن کاملP-27: Maintaining Position and Display Perspective in a Walking Simulator while Self-pacing on a Treadmill
We developed a feedback controller for a walking simulator composed of a treadmill and a rear projection screen. The controller keeps the subject centered and visual extent consistent across subjects and throughout individual trials while allowing subjects to set their own walking pace. 1. Objective and Background People with visual impairment (low-vision) are frequently prone to injury while w...
متن کاملReliability of Walking Speed, Stride Time and Stride Length Variability Using Feedback-controlled Treadmill
The purpose of this study was to evaluate the test-retest reliability of walking speed, stride time and stride length variability using a feedback-controlled treadmill. Ten subjects performed 3 trials of walking experiment for 5 min with a feedback-controlled treadmill. To check the reliability of gait parameters such as walking speed, average and variability (i.e. coefficient of variance, CV) ...
متن کاملThe cost of transport of human running is not affected, as in walking, by wide acceleration/deceleration cycles.
Although most of the literature on locomotion energetics and biomechanics is about constant-speed experiments, humans and animals tend to move at variable speeds in their daily life. This study addresses the following questions: 1) how much extra metabolic energy is associated with traveling a unit distance by adopting acceleration/deceleration cycles in walking and running, with respect to con...
متن کاملIdentification of muscle synergies associated with gait transition in humans
There is no theoretical or empirical evidence to suggest how the central nervous system (CNS) controls a variety of muscles associated with gait transition between walking and running. Here, we examined the motor control during a gait transition based on muscle synergies, which modularly organize functionally similar muscles. To this end, the subjects walked or ran on a treadmill and performed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 95 2 شماره
صفحات -
تاریخ انتشار 2003