Arterial input function and gray matter cerebral blood volume measurements in children

نویسندگان

  • Stephanie B. Withey
  • Jan Novak
  • Lesley MacPherson
  • Andrew C. Peet
چکیده

PURPOSE To investigate how arterial input functions (AIFs) vary with age in children and compare the use of individual and population AIFs for calculating gray matter CBV values. Quantitative measures of cerebral blood volume (CBV) using dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) require measurement of an AIF. AIFs are affected by numerous factors including patient age. Few data presenting AIFs in the pediatric population exists. MATERIALS AND METHODS Twenty-two previously treated pediatric brain tumor patients (mean age, 6.3 years; range, 2.0-15.3 years) underwent DSC-MRI scans on a 3T MRI scanner over 36 visits. AIFs were measured in the middle cerebral artery. A functional form of an adult population AIF was fitted to each AIF to obtain parameters reflecting AIF shape. The relationship between parameters and age was assessed. Correlations between gray matter CBV values calculated using the resulting population and individual patient AIFs were explored. RESULTS There was a large variation in individual patient AIFs but correlations between AIF shape and age were observed. The center (r = 0.596, P < 0.001) and width of the first-pass peak (r = 0.441, P = 0.007) were found to correlate significantly with age. Intrapatient coefficients of variation were significantly lower than interpatient values for all parameters (P < 0.001). Differences in CBV values calculated with an overall population and age-specific population AIF compared to those calculated with individual AIFs were 31.3% and 31.0%, respectively. CONCLUSION Parameters describing AIF shape correlate with patient age in line with expected changes in cardiac output. In pediatric DSC-MRI studies individual patient AIFs are recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method.

Kinetic analysis of 18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image derived input function is a non-invasive alternative but is challenging due to partial volume effects ca...

متن کامل

Measuring brain synaptic vesicle protein 2A with positron emission tomography and [18F]UCB-H

Introduction Brain distribution of synaptic vesicle protein 2A was measured with fluorine-18 UCB-H ([18F]UCB-H) and positron emission tomography (PET). Methods Images of synaptic density were acquired in healthy volunteers (two young participants and two seniors). Input function was measured by arterial blood sampling (arterial input function) and derived from PET images using carotid activit...

متن کامل

Cerebral blood flow with [15O]water PET studies using an image-derived input function and MR-defined carotid centerlines.

Full quantitative analysis of brain PET data requires knowledge of the arterial input function into the brain. Such data are normally acquired by arterial sampling with corrections for delay and dispersion to account for the distant sampling site. Several attempts have been made to extract an image-derived input function (IDIF) directly from the internal carotid arteries that supply the brain a...

متن کامل

Measurement of Cerebral Blood Flow and Cerebral Blood Volume in Humans Using Washout of Hyperoxic Contrast

Introduction Hyperoxic contrast-enhanced MRI, performed by increasing the inspired fraction of oxygen (FiO2>0.21), have been shown in numerous studies to produce positive contrast enhancement in T2-weighted images based on the blood oxygenation-dependent (BOLD) effect [1],[2],[3]. It has been long thought that hyperoxia substantially alters the hemodynamics of the brain, confounding attempts to...

متن کامل

Segmentation of Hemodynamics from Dynamic-Susceptibility-Contrast Magnetic Resonance Brain Images Using Sequential Independent Component Analysis

Dynamic-susceptibility-contrast magnetic resonance imaging, a popular perfusion imaging technique, records signal changes on images caused by the passage of contrast-agent particles in the human brain after a bolus injection of contrast agent. The temporal signal changes on different brain tissues characterize distinct blood supply patterns which are critical for the profound analysis of cerebr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2016