A versatile extracorporeal circuit for use during repair of descending and thoracoabdominal aortic aneurysms in high-risk patients with cardiac and/or pulmonary dysfunction: a novel approach to a significant perfusion management dilemma.

نویسندگان

  • Jeff T Edwards
  • D Mark Brown
  • Neil K Worrall
چکیده

The incidence of ischemic complications associated with repair of descending and thoracoabdominal aortic aneurysms has been significantly reduced by the use of distal aortic perfusion with moderate hypothermia, cerebral spinal fluid drainage, and segmental sequential clamping techniques. However, because the maintenance of proximal perfusion, the adequacy of left heart bypass (LHB), and the ability to ventilate patients on only one lung are all dependent on ventricular and pulmonary function, high-risk patients with descending and/or thoracoabdominal aortic aneurysms in the presence of cardiopulmonary insufficiency or instability present a difficult challenge for the surgical team. Traditional closed LHB circuits become nonfunctional in the event of cardiac arrest or refractory arrhythmias that create hemodynamic instability and are unable to provide necessary pulmonary support if the patient fails to ventilate adequately on one lung during thoracotomy. Furthermore, converting a patient from closed LHB to traditional venoarterial cardiopulmonary bypass (CPB) is frequently difficult, especially when the perfusionist works without the benefit of extra personnel to assist during such crises. Consequently, a modified extracorporeal circuit was designed to provide closed LHB with desired therapeutic adjuncts while also satisfying the additional need for a rapid infusion device, a source of supplemental ventilation/oxygenation, and, if necessary, the ability to convert the patient to venoarterial CPB conveniently in the event of cardiac and/or pulmonary failure during surgery to repair descending and/or thoracoabdominal aortic aneurysms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Correction of thoracic and thoracoabdominal aortic aneurysms. Central cannulation technique].

OBJECTIVE To demonstrate the viability of the use of extracorporeal circulation established between the left atrium and ascending aorta to induce deep hypothermia for correcting thoracic and thoracoabdominal aortic aneurysms. METHODS From January 1994 to July 2001, 38 patients (mean age, 54.6 +/- 12.7 years) were operated on as follows: 12 (31.6%) patients underwent repair of thoracoabdominal...

متن کامل

Open repair of extensive thoracoabdominal and thoracic aneurysm: a preliminary single-center experience with femorofemoral distal aortic perfusion with oxygenator and without cerebrospinal fluid drainage.

Thoracoabdominal aortic aneurysms (TAAA) and extensive thoracic descending aortic aneurysms (TDA) are not accessible through standard endovascular treatment. Fenestrated and branched endograft technology was developed rapidly without widespread application. The aim of this study was to review our open repair (OR) experience of TAAA and TDA. A total of 28 patients who underwent elective OR of TA...

متن کامل

Renal insufficiency after infrarenal abdominal aortic aneurysm reconstruction: An analysis of this risk factor in 45 patients

 Abstract Background: Renal insufficiency is a potential complication after infrarenal abdominal aortic aneurysm repair and is a significant risk factor for postoperative mortality and morbidity. The aim of this study was to analyze the effect of this risk factor, before and during operation. Methods: In this prospective study, between 2003 and 2006, 45 patients underwent repair of an infrarena...

متن کامل

Incidence, prevention, and management in spinal cord protection during TEVAR.

Until recently, patients with aneurysms of the thoracic and thoracoabdominal aorta had only one treatment option: open surgical repair. For those patients who could not tolerate an operation because of medical comorbidities, continued aneurysm enlargement and eventual rupture was a constant, yet unpredictable threat to their lives. Several studies have documented improved survival rates in thos...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 2004