Aerosol delivery with two ventilation modes during mechanical ventilation: a randomized study

نویسندگان

  • Jonathan Dugernier
  • Gregory Reychler
  • Xavier Wittebole
  • Jean Roeseler
  • Virginie Depoortere
  • Thierry Sottiaux
  • Jean-Bernard Michotte
  • Rita Vanbever
  • Thierry Dugernier
  • Pierre Goffette
  • Marie-Agnes Docquier
  • Christian Raftopoulos
  • Philippe Hantson
  • François Jamar
  • Pierre-François Laterre
چکیده

BACKGROUND Volume-controlled ventilation has been suggested to optimize lung deposition during nebulization although promoting spontaneous ventilation is targeted to avoid ventilator-induced diaphragmatic dysfunction. Comparing topographic aerosol lung deposition during volume-controlled ventilation and spontaneous ventilation in pressure support has never been performed. The aim of this study was to compare lung deposition of a radiolabeled aerosol generated with a vibrating-mesh nebulizer during invasive mechanical ventilation, with two modes: pressure support ventilation and volume-controlled ventilation. METHODS Seventeen postoperative neurosurgery patients without pulmonary disease were randomly ventilated in pressure support or volume-controlled ventilation. Diethylenetriaminepentaacetic acid labeled with technetium-99m (2 mCi/3 mL) was administrated using a vibrating-mesh nebulizer (Aerogen Solo(®), provided by Aerogen Ltd, Galway, Ireland) connected to the endotracheal tube. Pulmonary and extrapulmonary particles deposition was analyzed using planar scintigraphy. RESULTS Lung deposition was 10.5 ± 3.0 and 15.1 ± 5.0 % of the nominal dose during pressure support and volume-controlled ventilation, respectively (p < 0.05). Higher endotracheal tube and tracheal deposition was observed during pressure support ventilation (27.4 ± 6.6 vs. 20.7 ± 6.0 %, p < 0.05). A similar penetration index was observed for the right (p = 0.210) and the left lung (p = 0.211) with both ventilation modes. A high intersubject variability of lung deposition was observed with both modes regarding lung doses, aerosol penetration and distribution between the right and the left lung. CONCLUSIONS In the specific conditions of the study, volume-controlled ventilation was associated with higher lung deposition of nebulized particles as compared to pressure support ventilation. The clinical benefit of this effect warrants further studies. Clinical trial registration NCT01879488.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aerosol delivery during mechanical ventilation: from basic techniques to new devices.

Pressurized metered-dose inhalers (pMDIs) and nebulizers are routinely employed for aerosol delivery in mechanically ventilated patients. A significant proportion of the aerosol deposits in the ventilator circuit and artificial airway, thereby reducing the inhaled drug mass. Factors influencing aerosol delivery during mechanical ventilation differ from those in spontaneously breathing patients....

متن کامل

Factors affecting bronchodilator delivery in mechanically ventilated adults.

BACKGROUND Bronchodilators are increasingly being used in patients undergoing mechanical ventilation. There are multiple factors that affect bronchodilator delivery during mechanical ventilation. These factors can be classified into three categories: ventilator-related factors, circuit-related factors and device-related factors. AIMS The purpose of this paper is to review in depth each of the...

متن کامل

Intratracheal Administration of Lidocaine for Sedation of Patients under Mechanical Ventilation: A Double-Blind Randomized Clinical Trial

Background: Some patients with respiratory failure who are in need of mechanical ventilation require sedation to tolerate the inserted endotracheal tube (ETT) and other unpleasant stimuli. While a light sedation is satisfactory, deep sedation can interfere with the weaning process of patient from mechanical ventilator. Nevertheless, so far, the ideal regimen for sedatives and analgesics has not...

متن کامل

Pulmonary deposition of a nebulised aerosol during mechanical ventilation.

BACKGROUND There is increasing use of therapeutic aerosols in patients undergoing mechanical ventilation. Few studies have measured aerosol delivery to the lungs under these conditions with adequate experimental methods. Hence this study was performed to measure pulmonary aerosol deposition and to determine the reproducibility of the method of measurement during mechanical ventilation. METHOD...

متن کامل

High impact aerosol technology offers higher efficiency, but is not ready for prime time.

The therapeutic administration of medical aerosols has been a standard adjunct to treatment of critically ill patients since positive-pressure mechanical ventilators were introduced over 60 years ago, and most ventilators can operate a jet nebulizer in synchrony with mechanically delivered breaths. However, for the first 40 years, little was known about the efficiency of aerosol delivery during...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016