Parametric perfusion imaging with contrast-enhanced ultrasound in acute ischemic stroke.

نویسندگان

  • Martin Wiesmann
  • Karsten Meyer
  • Thomas Albers
  • Günter Seidel
چکیده

BACKGROUND AND PURPOSE Color-coded perfusion maps can be calculated from ultrasound harmonic gray-scale imaging data after ultrasound contrast agent bolus injection to analyze brain tissue perfusion. First reports indicate that this method can display cerebral perfusion deficits in acute ischemic stroke. We performed a prospective patient study to evaluate this approach. METHODS Thirty consecutive patients suffering from acute middle cerebral artery infarction who presented to our department within 12 hours after symptom onset were investigated with ultrasound perfusion harmonic imaging (PHI) after Levovist bolus injection. Color-coded perfusion maps were calculated from the ultrasound data. In addition, the original gray-scale images were analyzed in cine mode. Findings were compared with those of cranial CT. RESULTS All 30 patients suffered from acute ischemic stroke of the middle cerebral artery territory (median National Institutes of Health Stroke Scale score, 16 points). Twenty-three of the 30 patients (76.7%) had sufficient PHI insonation conditions. In 19 of these 23 patients (82.6%), a marked deficit in contrast enhancement could be visualized by initial PHI with the color-coded parameter images and cine-mode images. In 17 of the 23 (73.9%), the perfusion deficit was found on the parameter images. The area of hypoperfusion in the initial PHI investigation corresponded to the definite area of infarction in follow-up cranial CT. In 3 of 23 patients (13.0%), a perfusion deficit could be demonstrated in PHI, although the supplying artery was found patent by transcranial color-coded duplex sonography. CONCLUSIONS With PHI, it is possible to display cerebral perfusion deficits in acute ischemic stroke. PHI yields additional information on the perfusion state of the human brain compared with extracranial and transcranial color-coded duplex sonography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound perfusion imaging in acute middle cerebral artery infarction predicts outcome.

BACKGROUND AND PURPOSE Initial reports indicate that transcranial harmonic imaging after ultrasound contrast agent bolus injection (BHI) can detect cerebral perfusion deficits in acute ischemic stroke. We evaluated parametric images of the bolus washout kinetics. METHODS Twenty-three patients with acute internal carotid artery infarction were investigated with perfusion harmonic imaging after...

متن کامل

Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...

متن کامل

On the ability of ultrasound parametric perfusion imaging to predict the area of infarction in acute ischemic stroke.

PURPOSE Cerebral perfusion deficits in acute ischemic stroke can be detected by means of transcranial harmonic imaging after ultrasound contrast agent bolus injection. We evaluated five different parameters of the bolus kinetics as parametric images and correlated areas of disturbed perfusion with the area of definite infarction. MATERIALS AND METHODS Perfusion harmonic imaging after SonoVue ...

متن کامل

Ultrasound microbubble destruction imaging in acute middle cerebral artery stroke.

BACKGROUND AND PURPOSE Cerebral perfusion imaging in acute stroke assists in determining the subtype and the severity of ischemia. Recent studies in perfusion models and in healthy volunteers have shown that ultrasound perfusion imaging based on microbubble destruction can be used to assess tissue perfusion. We applied ultrasound microbubble destruction imaging (MDI) to identify perfusion defic...

متن کامل

Combined low-dose contrast-enhanced MR angiography and perfusion for acute ischemic stroke at 3T: A more efficient stroke protocol.

BACKGROUND AND PURPOSE There is need to improve image acquisition speed for MR imaging in evaluation of patients with acute ischemic stroke. The purpose of this study was to evaluate the feasibility of a 3T MR stroke protocol that combines low-dose contrast-enhanced MRA and dynamic susceptibility contrast perfusion, without additional contrast. METHODS Thirty patients with acute stroke who un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 2004