Modulation of cytochrome c spin states by lipid acyl chains: a continuous-wave electron paramagnetic resonance (CW-EPR) study of haem iron.
نویسندگان
چکیده
This work is a systematic study, showing a clear correlation between the nature of the lipid acyl chain and the spin states of cytochrome c interacting with different types of lipid membranes. According to the lipid acyl chain type, and the head group charge present in the bilayer, three spin states of cytochrome c were observed in different proportions: the native cytochrome c low spin state with rhombic symmetry (spin 1/2, g axially=3.07 and g radially=2.23), a low spin state with less rhombic symmetry (spin 1/2, g(1)=2.902, g(2)=2.225, and g(3)=1.510) and the high spin state (spin 5/2, g axially=6.0 and g radially=2.0). The proportion of the spin states of cytochrome c bound to bilayers was also dependent on the lipid/protein ratio, suggesting the existence of two or more protein sites interacting with the lipids. The lipid-induced alterations in the symmetry and spin states of cytochrome c exhibited partial reversibility when the ionic strength was increased, which reinforces the crucial role played by the electrostatic interaction with the lipid bilayer. Different cytochrome c spin states exhibited corresponding modifications in the haemprotein UV/visible spectra, particularly in the Q-band associated with loss of the 695 nm band and appearance of a band in the region of 600-650 nm. The observed reactivity of cytochrome c with oxidized forms of unsaturated lipids reinforces the possibility of the acyl chain insertion in the haemprotein structure.
منابع مشابه
Demystifying EPR: A Rookie Guide to the Application of Electron Paramagnetic Resonance Spectroscopy on Biomolecules
Electron Paramagnetic Resonance (EPR) spectroscopy, also known as Electron Spin Resonance(ESR) especially among physicists, is a strong and versatile spectroscopic method forinvestigation of paramagnetic systems, i.e. systems like free radicals and most transition metalions, which have unpaired electrons. The sensitivity and selectivity of EPR are notable andintriguing as compared to other spec...
متن کاملNonlinear electron paramagnetic resonance studies of the interaction of cytochrome c oxidase with spin-labeled lipids in gel-phase membranes.
The interaction of lipids, spin-labeled at different positions in the sn-2 chain, with cytochrome c oxidase reconstituted in gel-phase membranes of dimyristoylphosphatidylglycerol has been studied by electron paramagnetic resonance (EPR) spectroscopy. Nonlinear EPR methods, both saturation transfer EPR and progressive saturation EPR, were used. Interaction with the protein largely removes the f...
متن کاملThe continuous wave electron paramagnetic resonance experiment revisited.
When the modulation frequency used in continuous wave electron paramagnetic resonance (cw EPR) spectroscopy exceeds the linewidth, modulation sidebands appear in the spectrum. It is shown theoretically and experimentally that these sidebands are actually multiple photon transitions, sigma(+)+kxpi, where one microwave (mw) sigma(+) photon is absorbed from the mw radiation field and an arbitrary ...
متن کاملElectron paramagnetic resonance study of the high- and low-spin forms of cytochrome P-450 in liver and in liver microsomes from a methylcholanthrene-treated rabbit.
The high- and low-spin forms of cytochrome P-450 were observed by electron paramagnetic resonance (epr) in a liver slice and in hepatic microsomes from a rabbit injected with methylcholanthrene. Quantitation of the epr absorption of these two chemical species and comparison with a preparation from a control rabbit showed that the single injection of drug increased the concentration of cytochrom...
متن کاملEvaluation and comparison of pulsed and continuous wave radiofrequency electron paramagnetic resonance techniques for in vivo detection and imaging of free radicals.
The performance of two electron paramagnetic resonance (EPR) spectrometers/imagers, one configured in pulsed mode and the other in continuous wave (CW) mode, at an operating frequency of 300 MHz is compared. Using the same resonator (except for altered Q-factors), identical samples and filling factors in the two techniques have been evaluated for their potentials and limitations for in vivo spe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Biochemical journal
دوره 370 Pt 2 شماره
صفحات -
تاریخ انتشار 2003