Fast spin-echo imaging of the neck: comparison with conventional spin-echo, utility of fat suppression, and evaluation of tissue contrast characteristics.

نویسندگان

  • J S Lewin
  • H D Curtin
  • J S Ross
  • J L Weissman
  • N A Obuchowski
  • J A Tkach
چکیده

PURPOSE To determine whether fast spin-echo sequences could replace conventional spin-echo methods in the evaluation of head and neck neoplasms and associated adenopathy and to evaluate differences in tissue contrast characteristics between conventional spin-echo and fast spin-echo examinations of head and neck disease. METHODS Twenty-seven patients with squamous cell carcinoma were imaged on a 1.5-T imager with both conventional spin-echo and fast spin-echo sequences with identical section thickness and position. Twenty-one of the 27 fast spin-echo studies were performed with frequency-selective fat suppression. Three radiologists independently evaluated the images using a five-point scale to compare primary lesion margin definition and conspicuity, lymph node margin definition and conspicuity, gross motion artifact, and flow artifact. Quantitative percent contrast and contrast-to-noise ratios were calculated and compared in 7 cases with fat-suppressed fast spin-echo. RESULTS Fast spin-echo was preferred by all three readers for lesion margin conspicuity and lymph node conspicuity. Gross motion and flow artifact demonstrated trends toward reader preference for fast spin-echo. Quantitative contrast values for fast spin-echo were significantly greater than those for conventional spin-echo. CONCLUSIONS Fast spin-echo with fat suppression can replace conventional spin-echo at a time savings of more than 50% and improves tissue contrast and the conspicuity and definition of margins for primary lesions and lymph nodes. Fat-suppression heterogeneity remains the major limitation of this technique. Thus, careful attention to fat-suppression failure and unwanted water saturation is essential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fat-suppressed MR of the orbit and cavernous sinus: comparison of fast spin-echo and conventional spin-echo.

PURPOSE To compare T2-weighted fat-suppressed fast spin-echo imaging with fat-suppressed conventional spin-echo imaging in the detection of normal intraorbital and pericavernous anatomy and orbital disease, and to determine the efficacy of fat saturation with T2-weighted fast spin-echo imaging of the cavernous sinus. METHODS Contrast-to-noise ratios of normal intraorbital anatomy were calcula...

متن کامل

I-42: MRI Evaluation of Congenital Uterine Anomalies

Mullerian duct anomalies are an uncommon but often treatable cause of infertility. Patients with müllerian duct anomalies are known to have a higher incidence of infertility, repeated first-trimester spontaneous abortions, fetal intrauterine growth retardation, fetal malposition, preterm labor, and retained placenta. The role of imaging is to help detect, diagnose, and distinguish surgically co...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 15 7  شماره 

صفحات  -

تاریخ انتشار 1994